期刊文献+

一种微量泵的结构设计及动力学分析 被引量:3

Structural Design and Dynamic Analysis of a Micro-pump
下载PDF
导出
摘要 国内医疗、生化领域中使用的微量泵都是进口国外的,其技术被国外垄断。为了解决该难题,设计了一种主要应用于体外诊断分析仪的微量泵。采用了步进电机控制三位四通阀的创新设计,从而大大提高了微量泵的精度,并且对微量泵的各个模块在Solidworks软件中进行结构仿真设计,通过ADAMS软件进行了整体运动模块的性能分析,验证了微量泵的性能合理,并且计算了微量泵的进样精度和进样量。经计算分析表明:此结构设计精度高,简化了体外诊断分析仪的液路系统。 Micro-pump used in domestic medical and biochemical field relies on import and the technique is monopolized. In order to solve this problem, a micro-pump which is mainly used in invitro diagnostic analyzer is designed. The innovative design of three-position four-way valve controlled by stepping motor was adopted, which greatly improved the precision of micro-pump. And the structure simulated design of each module of micro-pump in Solidworks software was carried out. The performance of the whole motion module was analyzed by ADAMS software, and the rational performance of the micro-pump was verified. The injection accuracy and injection volume of the micro-pump were also calculated. The computed analysis show that his structure design has high precision, which simplifies the fluid system of the in vitro diagnostic analyzer, and provides a theoretical basis and reference value for the medical industry.
作者 董小杏 朱维兵 DONG Xiaoxing;ZHU Weibing(College of Physics and Engineering,Chengdu Normal University, Chengdu Sichuuan 611130,China;School of Mechanical Engineering, Xihua University,Chengdu Sichuan 610039, China)
出处 《机床与液压》 北大核心 2019年第15期119-122,共4页 Machine Tool & Hydraulics
基金 四川省国际科技合作与交流研发项目(2017HH0049) 成都师范2018年校级科研项目(CS18ZB06)
关键词 微量泵 三位四通阀 步进电机 动力学分析 ADAMS Micro-pump Three-position four-way valve Stepper motor Dynamic analysis ADAMS
  • 相关文献

参考文献3

二级参考文献8

共引文献65

同被引文献30

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部