摘要 就接触式点胶阀在喷涂胶液保护膜时,在保护膜中存在气泡或真空包,胶水在低压环境中析出气体等质量问题,提出设置压力反馈回路,改变进胶方式,加大进胶管直径,提高阀室内工作压力等解决方案,创新设计了一款新型接触式点胶阀。应用结果表明:新型接触式点胶阀具有控胶迅速准确,出胶连贯性好,不形成气泡或真空包,具有广泛的推广应用价值。 When the contact type glue valve is used to spray protective film of the glue liquid, there are quality problems, like bubbles or vacuum packages in the protective film, and gas precipitated from glue in low pressure. Therefore, the solutions are put forward by designing a pressure feedback loop, changing the way of feeding, increasing the diameter of the rubber pipe and improving the working pressure of the valve and so on. A creative type of contact valve was designed. The application results show that the new contact valve has the characteristics of rapid and accurate glue control, good consistency and no bubble or vacuum package, which has wide application value.
作者 林和德 林明山 温明生 LIN Hede;LIN Mingshan;WEN Mingsheng(Zhangzhou Institute of Technology, Zhangzhou Fujian 363000, China;Shenzhen Yuanshuo Automation Technology Co., Ltd., Shenzhen Guangdong 518000, China)
出处 《机床与液压》 北大核心 2019年第15期131-133,144,共4页 Machine Tool & Hydraulics
基金 福建省教育厅科技计划项目(JB09279)
关键词 点胶阀 空气泡 压力反馈 弹性隔膜 Contact type glue valve Bubble Pressure feedback Elastic diaphragm
  • 相关文献

参考文献3

二级参考文献24

  • 1袁新明,贺治国,毛根海.用RNG k-ε紊流模型对截止阀三维紊流流动的数值模拟[J].流体机械,2006,34(2):34-38. 被引量:31
  • 2黄道见.离心泵叶轮内汽蚀发生的理论探讨[J].农机化研究,2006,28(6):88-89. 被引量:10
  • 3牟介刚,张生昌,邓鸿英,郑水华.离心泵汽蚀判据的研究[J].农业机械学报,2006,37(9):97-99. 被引量:21
  • 4Singhal A K,Athavale M M,Li H Y,et al.Mathematical Basis And Validation of The Full Cavitation Model[J].ASME Journal of Fluids Engineering,2002,124(9):617-624.
  • 5Bakir F,Rey R,Gerber A G,et al.Numerical and Experimental Investigations of The Cavitating Behavior of An Inducer[J].Int J Rotating Machinery,2004,10:15-25.
  • 6金志江,匡继勇.一种带有先导阀的截止阀:中国,200810120906.1[P].2009-02-04.
  • 7Hydraulic institute standards[S]. Hydraulic I nstitute,9 Sy Ivan Way, Suite 360,Parsippany, NJ 07,054-3802.
  • 8Xavier E, Eduard E, Mohamed F, et al. Detect ion of cavitation in hydraulic turbines [ J ]. Mechanical Sys- tems and Signal Processing,2006,20(4) ,983-1007.
  • 9Alfayez L, Mba D, Dyson G. The application of acoustic emission for detecting incipient car itation and the best efficiency of a 60 kW centfifug al pump: case study [J]. NDT& E International, 2005, 38(5) :354-358.
  • 10YOON J Y, BYUN S J, YANG J M, LEE D H. Numerical analysis of the 3-D flow field in a globe valve trim under high pressure drop [ J]. Journal of Fluid Machinery,2001 (4) : 14 - 20.