摘要 依据JJF 1059.1—2012《测量不确定度评定与表示》和GB/T 27411—2012《检测实验室中常用不确定度评定方法与表示》两个不确定度相关标准,对GB 5009.15—2014《食品安全国家标准食品中镉的测定》中原子吸收分光光度计石墨炉法测定食品中镉含量的测量不确定度进行评定,根据原子吸收分光光度计石墨炉法测定食品中镉含量的分析方法,建立数学模型,找出检测过程中影响结果的不确定度分量来源并进行评定分析,最终得出不确定度评定结果。 According to the related provisions of the uncertainties in JJF 1059.1-2012 and GB/T 27411-2012, the uncertainties in the determination of cadmium content in food by graphite furnace method with atomic absorption spectrophotometer in GB 5009.15-2014 were evaluated, the mathematical model was established, and the source of the uncertainty component influencing the determination results was found out, and finally the evaluation results were obtained.
作者 王超 刘杨 蒋祥飞 汤有宏 WANG Chao;LIU Yang;JIANG Xiangfei;TANG Youhong(Gujing Gongjiu Co. Ltd., Bozhou, Anhui 236820;Anhui Engineering Research Center of Solid-state Brewing, Bozhou, Anhui 236820, China)
出处 《酿酒科技》 2019年第8期112-116,121,共6页 Liquor-Making Science & Technology
关键词 原子吸收 不确定度 cadmium atomic absorption uncertainty
  • 相关文献

参考文献1

二级参考文献4

  • 1JJFl059—1999中华人民共和国国家计量技术规范.测量不确定评定与表示[s].北京:中国计量出版社,1999.
  • 2GB/T15009.15—2003中华人民共和国国家标准.食品卫生检验方法理化部分.食品中镉的测定[s].北京:中国标准出版社,2003.
  • 3JJGl96—2006中华人民共和国国家计量检定规程.常用玻璃量器[S].北京:中国计量出版社,2007.
  • 4周娅,杨定清,谢永红,黄惠兰,王棚.石墨炉原子吸收光谱法测定金银花中铅镉的研究[J].中国测试,2009,35(5):88-90. 被引量:16