摘要
依据溧阳市沙河水库水文站的自动蒸发仪观测资料及同步的人工观测蒸发量,分别进行F检验、显著性检验、Q检验和回归分析,来分析FFZ-01X型和CQS.FFH-2型浮子式遥测水面蒸发仪的精度,为推进自动化蒸发监测提供经验和技术支撑。
According to the observation data of automatic evaporator at the hydrological station of Shahe reservoir and the synchronous evaporation data by manual observation in Liyang City,the F test,the significance test,the Q test and the regression analysis were respectively carried out to analyze the accuracy of FFZ-01 X type and CQS.FFH-2 float-type remote water surface evaporator to provide experience and technical support for the promotion of automated evaporation monitoring.
作者
胡尊乐
黄炜
唐大伟
汪姗
潘芷璐
HU Zunle;HUANG Wei;TANG Dawei;WANG Shan;PAN Zhilu(Changzhou Hydrology and Water Resources Surveys Bureau of Jiangsu Province,Changzhou 213022,Jiangsu;Jiangsu Hydrology and Water Resources Survey Bureau,Nanjing 210029,Jiangsu;Hohai University,Nanjing 210098,Jiangsu)
出处
《江苏水利》
2019年第8期7-13,共7页
Jiangsu Water Resources
关键词
浮子式蒸发仪
自动观测
蒸发量
float-type evaporator
automatic observation
evaporation