Evaluation of CdZnTe spectrometer performance in measuring energy spectra during interventional radiology procedure 被引量:2

Evaluation of CdZnTe spectrometer performance in measuring energy spectra during interventional radiology procedure
下载PDF
导出
摘要 Interventional radiology has been beneficial for patients for over 30 years of age with the combination of diagnostic and therapeutic methods. The radiation affecting occupationally exposed workers should be evaluated by means of the energy spectra and flux of X-rays in the treatment room. The present study aims to obtain the energy spectra of interventional procedures and study the capability of some detectors to evaluate the dose in interventional procedures. These measurements were taken by silicon-drift, CdTe, and CdZnTe detectors. The energy spectra were corrected by the energy-response curve of each detector. The energy-response curves of silicon-drift and CdTe detectors provided by the manufacturers specification were used. The energy response of the CdZnTe detector was measured by 133Ba and 152Eu γ sources. The experimental data were compared with the simulation results, and their perfect agreement provides a way to correct the energy or dose response, which can be used for the personal dosimeter developed by our group. Moreover, the measured energy spectra can be used in individual radiation protection. The present study shows that the CdZnTe detector is a good candidate detector in interventional procedures. Interventional radiology has been beneficial for patients for over 30 years of age with the combination of diagnostic and therapeutic methods. The radiation affecting occupationally exposed workers should be evaluated by means of the energy spectra and flux of X-rays in the treatment room. The present study aims to obtain the energy spectra of interventional procedures and study the capability of some detectors to evaluate the dose in interventional procedures. These measurements were taken by silicon-drift, Cd Te, and Cd Zn Te detectors. The energy spectra were corrected by the energy-response curve of each detector. The energy-response curves of silicon-drift and Cd Te detectors provided by the manufacturers specification were used. The energy response of the Cd Zn Te detector was measured by 133Ba and 152Eu c sources. The experimental data were compared with the simulation results, and their perfect agreement provides a way to correct the energy or dose response, which can be used for the personal dosimeter developed by our group.Moreover, the measured energy spectra can be used in individual radiation protection. The present study shows that the Cd Zn Te detector is a good candidate detector in interventional procedures.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第9期55-60,共6页 核技术(英文)
基金 supported by the National Natural Science Foundation of China(No.11705123) Natural Science Foundation of Jiangsu Province(No.BK20160306) China Postdoctoral Science Foundation(No.2016M591911) the Project of the State Key Laboratory of Radiation Medicine and Protection,Soochow University(No.GZN1201801)
关键词 INTERVENTIONAL RADIOLOGY procedures Energyresponse CURVE Energy spectrum Radiation protection Interventional radiology procedures Energyresponse curve Energy spectrum Radiation protection
  • 相关文献

同被引文献18

引证文献2

二级引证文献3

  • 1王启奇,张湘,田立朝,马燕云,孙乙文.闪烁光纤中宇宙线缪子的荧光光子计数测量[J].核技术,2023,46(10):15-22.
  • 2Xi‑Yang Wang,Hong‑Yu Zhang,De‑Qing Fang,Wan‑Bing He,Xiao‑Long Wang,Qi‑Bin Zheng,Shi‑Ming Zou.Design and performance of a high-speed and low-noise preamplifier for SiPM[J].Nuclear Science and Techniques,2023,34(11):93-102. 被引量:1
  • 3Rui He,Xiao‑Yang Niu,Yi Wang,Hong‑Wei Liang,Hong‑Bang Liu,Ye Tian,Hong‑Lin Zhang,Chao‑Jie Zou,Zhi‑Yi Liu,Yun‑Long Zhang,Hai‑Bo Yang,Ju Huang,Hong‑Kai Wang,Wei‑Jia Han,Bei Cao,Gang Chen,Cong Dai,Li‑Min Duan,Rui‑Rui Fan,Fang‑Fa Fu,Jian‑Hua Guo,Dong Han,Wei Jiang,Xian‑Qin Li,Xin Li,Zhuo‑Dai Li,Yu‑Tie Liang,Shun Liao,De‑Xu Lin,Cheng‑Ming Liu,Guo‑Rui Liu,Jun‑Tao Liu,Ze Long,Meng‑Chen Niu,Hao Qiu,Hu Ran,Xiang‑Ming Sun,Bo‑Tan Wang,Jia Wang,Jin‑Xiang Wang,Qi‑Lin Wang,Yong‑Sheng Wang,Xiao‑Chuan Xia,Hao‑Qing Xie,He‑Run Yang,Hong Yin,Hong Yuan,Chun‑Hui Zhang,Rui‑Guang Zhao,Ran Zheng,Cheng‑Xin Zhao.Advances in nuclear detection and readout techniques[J].Nuclear Science and Techniques,2023,34(12):281-358. 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部