期刊文献+

广州地区绿色办公建筑夏季空调热舒适研究 被引量:4

Study on thermal comfort of summer air conditioning in green office buildings in Guangzhou
下载PDF
导出
摘要 选取广州地区的4栋绿色办公建筑,采用长期监测运行数据结合主观问卷调研的方法,对其室内热环境及主观满意度进行了调研。结果表明,虽然调研案例的室内热环境达标率较低,但只有21%的使用者对热环境表示不满意。分析原因为人员的主观满意度会受到“原谅因子”的影响,使得实际评价结果偏好。通过对人员主观感受值AMV与室内温度、湿满意度与相对湿度分别进行线性拟合得出:广州地区绿色办公建筑的夏季室内舒适温度为25.94℃,舒适区温度范围为23.13~28.76℃;舒适相对湿度为50.5%,舒适相对湿度上限为83.6%。 Investigates the indoor thermal environment and subjective satisfaction of four green office buildings in Guangzhou by long-term monitoring operation data and subjective questionnaire survey.The results show that although the indoor thermal environment compliance rate is low,only 21%of occupants are unsatisfied with the thermal environment.The reason is that the subjective satisfaction of the occupants will be affected by the forgiveness factor,which makes the actual evaluation result preference.According to the linear fitting of subjective perception AMV and indoor temperature,actual humidity perception and relative humidity,concludes that the indoor comfort temperature of green office buildings in Guangzhou in hummer is 25.94℃,the comfort zone temperature range is 23.13 to 28.76℃,the comfort relative humidity is 50.5%,and the upper limit of comfort relative humidity is 83.6%.
作者 孙昀灿 吕石磊 王冉 Sun Yuncan;Lu Shilei;Wang Ran(Tianjin University,Tianjin,China)
机构地区 天津大学
出处 《暖通空调》 2019年第8期18-22,共5页 Heating Ventilating & Air Conditioning
基金 “十三五”国家重点研发计划项目课题“绿色建筑节能环保技术适应性研究”(编号:2016YFC0700103)
关键词 广州地区 绿色建筑 热舒适 主观满意度 线性拟合 Guangzhou green building thermal comfort subjective satisfaction linear fitting
  • 相关文献

同被引文献41

引证文献4

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部