摘要 本文以上海地铁1号线部分地下车站为研究对象,通过调研与实测的方式研究了地铁站内的环境状况。实验结果表明:地铁站台内以温湿度为代表的微气候能够满足乘客的需求。CO2的浓度水平略高于0.10%的标准值,换乘站的浓度比非换乘站的浓度明显高出很多。在地铁站内,颗粒物浓度过高,PM10的平均浓度范围为200~800μg/m3,超标比较严重,晴天的站台内颗粒物浓度普遍高于雨天的站台内颗粒物浓度,特别是细颗粒物PM2.5的浓度所占比例很大。 This paper takes the underground station of Shanghai metro line 1 as the research object and studies the environmental conditions in the subway station through investigation and measurement. The experimental results show that the microclimate represented by temperature and humidity can meet the needs of passengers. The concentration level of CO2 was slightly higher than that of 0.10%, and the concentration of the transfer station was significantly higher than that of the non-transfer station. In metro stations, the particle concentration is too high, the average PM10 concentration range is 200~00 μg/m3, overweight is more serious, sunny platform inside the particle concentration is generally higher than rainy particle concentration in the platform, especially fine particulate matter concentrations of PM2.5 proportion is very big.
作者 王迪 沈恒根 WANG Di;SHEN Heng-gen(College of Environment Science and Engineering,Donghua University)
出处 《建筑热能通风空调》 2019年第8期44-47,共4页 Building Energy & Environment
关键词 地铁 温度 相对湿度 CO2 颗粒物 metro station temperature relative humidity CO2 particulate matters
  • 相关文献

参考文献2

二级参考文献16

  • 1李涛,张建鹏,陈炳耀,梁辉,麦哲恒.广州市轨道交通卫生状况[J].华南预防医学,2006,32(5):54-55. 被引量:8
  • 2张松乐.近地面大气微生物本底调查研究进展[J].中国微生态学杂志,1996,8(5):40-44. 被引量:8
  • 3中华人民共和国卫生部.GB9672-1996公共交通等候室卫生标准[S].北京:中国标准出版社,2005.
  • 4中华人民共和国卫生部.公共场所集中空调通风系统卫生规范[R].北京:中国标准出版社,2006.
  • 5PARK DU, HA KC. Characteristics of PM10, PM25, CO2 and CO monitored in interiors and platforms of subway train in Seoul, Korea [J]. Environ Int, 2008, 34( 5 ): 629-634.
  • 6GOMEZ-PERALES JE, COLVILE RN, FERNANDEZ-BREMAUNTZ A A, et al. Bus, minibus, metro inter-comparison of commuters' exposure to air pollution in Mexico City [J]. Atmos Environ, 2007, 41 (4): 890-901.
  • 7CHAN LY, LAU WL, WANG XM, et al. Preliminary measurements of aromatic VOCs in public transportation modes in Guangzhou, China [ J ]. Environ Int, 2003, 29(4): 429-435.
  • 8CHAN LY, LAU WL, LEE SC, et al. Commuter exposure to particulate matter in public transportation modes in Hong Kong [ J ]. Atmos Environ, 2002, 36( 21 ): 63-373.
  • 9中华人民共和国卫生部.GB/T18203-2000室内空气中溶血性链球菌卫生标准[S].北京:中国标准出版社,2001.
  • 10刘承东.关于地铁设计规范中空调新风量取值问题的探讨[C]//中国制冷学会2009年学术年会论文集.天津:中国制冷学会,2009.

共引文献19

同被引文献31

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部