摘要
本文以某项目净化装置酸性气体脱除单元为基础,结合实际工作分析了配管工作中低温甲醇洗装置板式塔的管口方位设计方法和注意事项。
Based on the acid gas removal of purification plant, the author analyzed and summarized the piping arrangement and nozzle orientation design of the high tray tower for piping discipline, combined with the actual piping engineering experience, tray tower nozzle design method and matters needing attention have been mentioned.
作者
涂林
Tu Lin(Sinopec Ningbo Engineering Co., Ltd., Ningbo 315103, China)
出处
《广东化工》
CAS
2019年第15期156-157,155,共3页
Guangdong Chemical Industry
关键词
酸性气体脱除
管口方位
塔内件
管道设计
Acid gas removal
nozzle orientation
tower internals