摘要
沼气工程中室外罐区仪表可能因遭受雷击,造成整个生产装置停车。针对此类问题,介绍了仪表信号防雷的主要措施以及信号防雷浪涌保护器的主要类型及参数,论述了信号防雷浪涌保护器的具体设置原则及安装方法等,并结合实际沼气工程项目厌氧罐区仪表的防雷设计进行应用。
In biogas engineering,the instrument in outdoor tank area may be struck by lightning,which may cause the whole production plant to stop.Aiming at these problems,to introduce the main measures of instrument signal lightning protection and the main types and parameters of signal lightning surge protector,discuss the specific setting principles and installation methods of signal lightning surge protector.And also describe the application of instrument lightning protection based on the engineering of anaerobic tank area in biogas project.
作者
王冲
Wang Chong(China Haisum Engineering Co.,Ltd.,Shanghai 200031,China)
出处
《山东化工》
CAS
2019年第16期174-175,180,共3页
Shandong Chemical Industry
关键词
信号浪涌保护器
厌氧罐仪表
室外仪表防雷
隔爆型
signal surge protector
anaerobic tankinstrument
outdoor instrument lightning protection
exd type