期刊文献+

浅析1000MW等级锅炉低负荷分隔屏偏差特性

Analysis of Deviation Characteristics of Low Load Separation Screen of 1000MW Grade Boiler
下载PDF
导出
摘要 本文以某电厂百万高效超超临界锅炉为研究对象,结合现场运行壁温和模拟计算结果来探究低负荷分隔屏偏差特性。在现有基础上,吸取经验教训,优化锅炉设计方案,有针对性的提出各项改进措施,提升锅炉的各项性能指标;同时对锅炉受热面进行优化,可合理降低成本。 This paper takes the high - efficiency ultra - supercritical boiler of a Power Plant as the research object, and combines the field running wall temperature and simulation calculation results to explore the deviation characteristics of low - load separation screen. On the basis of the existing, learn lessons and optimize the boiler design plan, propose various improvement measures to improve the performance indicators of the boiler, optimize the boiler heating surface, and reduce the cost reasonably. More boiler markets offer more space.
作者 殷亚宁 郭馨 Yin Yaning;Guo Xin(State Key Laboratory of Efficient and Clean Coal-fired Utility Boilers ( Harbin Boiler CoMPAny Limited) ,Harbin 150046,China;Harbin Boiler Co.,Ltd.,Harbin 150046,China)
出处 《锅炉制造》 2019年第5期1-4,共4页 Boiler Manufacturing
关键词 数值模拟 1000MW 低负荷 偏差计算 Numerical simulation 1000MW low load deviation calculation