期刊文献+

Ahmed青光眼阀治疗玻璃体切割术后新生血管性青光眼1例 被引量:2

One case of Ahmed glaucoma valve for neovascular glaucoma after vitrectomy
下载PDF
导出
摘要 新生血管性青光眼(NVG)是药物和常规手术均很难控制眼压的一种难治性青光眼。对于玻璃体切割术后合并NVG患者的有效治疗方法较少,Ahmed青光眼阀植入术是一种安全有效的手术方式。本研究报道了1例因糖尿病视网膜病变已行4次眼科手术、眼压顽固不降的NVG患者,行Ahmed青光眼阀植入术后眼压控制理想。 Neovascular glaucoma(NVG) is a refractory glaucom a that is difficult to control intraocular pressure by drugs and routine surgery. There are few effective treatment methods for NVG after vitrectomy, and Ahmed glaucoma valve implantation is a safe and effective surgical method. This study reported a case of NVG with diabetic retinopathy who had undergone four ophthalmic operations and intraocular pressure persistence. The control of intraocular pressure was ideal after Ahmed glaucoma valve implantation.
作者 王丹丹 王伟伟 杨欣 刘建荣 WANG Dan-dan;WANG Wei-wei;YANG Xin;LIU Jian-rong(Xi'an Fourth Hospital/ Shaanxi Eye Hospital/ Guangren Hospital Affiliated to Xi'an Jiaotong University, Xi'an 710004, China)
出处 《临床医学研究与实践》 2019年第26期7-8,共2页 Clinical Research and Practice
基金 国家自然科学基金项目(No.81500719) 陕西省创新能力支撑计划项目(No.2018KJXX-091)
关键词 新生血管性青光眼 玻璃体切割 AHMED 青光眼阀 neovascular glaucoma vitrectomy Ahmed glaucoma valve
  • 相关文献

参考文献3

二级参考文献19

  • 1陈虹,张舒心,刘磊,林丁,唐炘,孙丽,王涛,王华,王宁利.Ahmed青光眼阀植入术的中远期疗效评价[J].中华眼科杂志,2005,41(9):796-802. 被引量:58
  • 2Quigley HA,Broman AT.The number of people with glaucomaworldwide in 2010 and 2020[J].Br J Ophthalmol,2006,90(3):262-267.
  • 3Syed HM,Law SK,Nam SH,et al.Baerveldt-350 implant versusAhmed valve for refractory glaucoma:a case-controlled comparison[J].J Glaucoma,2004,13(1):38-45.
  • 4Taglia DP,Perkins TW,Gangnon R,et al.Comparison of theAhmed glaucoma valve,the Krupin eye valve with disk,and thedouble-plate Molteno implant[J].J Glaucoma,2002,11(4):347-353.
  • 5Murali A.The efficacy of Ahmed glaucoma valve drainage devicesin cases of adult refractive glaucoma in Indian eyes[J].Indian J Ophthalmol,2010,58(3):259-261.
  • 6Souza C,Tran DH,Loman J,et al.Long-term outcomes of Ahmedglaucoma valve implantation in refractory glaucomas[J].Am J Ophthalmol,2007,144(6):893-900.
  • 7Smith SL,Starita RJ,Fellman RL,et al.Early clinical experiencewith the Baerveldt 350-mm2 glaucoma implant and associatedextraocular muscle imbalance[J].Ophthalmology,1993,100(6):914-918.
  • 8Hinkle DM,Zurakowski D,Ayyala RS.A comparison of thepolypropylene plate Ahmed glaucoma valve to the silicone plateAhmed glaucoma flexible valve[J].Eur J Ophthalmol,2007,17(5):696-701.
  • 9Ishida K,Netland PA,Costa VP,et al.Comparison ofpolypropylene and silicone Ahmed glaucoma valves[J].Ophthalmology,2006,113(8):1320-1326.
  • 10Coleman AL,Hill R,Wilson MR,et al.Initial clinical experiencewith the Ahmed glaucoma valve implant[J].Am J Ophthalmol,1995,120(1):23-31.

共引文献38