摘要
针对某公司2#75000Nm^3/h空分上塔氮气纯度不合格的问题进行了系统分析,并采取了调整空分运行参数、短时间系统停车、对上塔进行冲压、反吹等措施,但问题仍未解决。最后结合空分系统检修,清理上塔液氮分布器及其上部过滤网后,问题得到解决。
This paper systematically analyzes a company 2# 75 000 Nm 3/h air separation tower nitrogen purity is qualified,and take the adjustment of air separation operation parameters,short time parking,the upper tower punching,anti-blowing and other measures,but the problems have not been solved. Finally,the air separation system maintenance,cleaning on the tower and the upper filter liquid nitrogen distributor after the problems are solved.
作者
秦悦
QIN Yue(Shougang Jingtang United Steel Co.,Ltd.,Tangshan 063200,China)
出处
《低温与特气》
CAS
2019年第4期22-25,共4页
Low Temperature and Specialty Gases
关键词
空分设备
上塔氮气纯度
漏液
冷箱压力
液体分布器
air separation plant
nitrogen purity of upper tower
liquid leakage
cold box pressure
liquid distributors