摘要
文章基于FDS技术,提出油浸式变压器绝缘系统的评估方法。通过获取油浸式变压器油纸参数,分析油纸介质的电位移与油纸绝缘老化状态之间的关系,完成油纸绝缘老化状态评估。试验分析证明,该评估方法具有有效性,可以有效降低变压器绝缘故障引发事故的发生率。
Based on FDS technology, this paper puts forward an state evaluation method for the insulation system of oil immersed transformer. By identifying oil-paper parameters of the oil immersed transformer and analyzing the relationship between the electric displacement of the oil-paper medium and the insulation aging state of the oil-paper, the insulation aging state of the oil-paper is evaluated. The test analysis proves that the evaluation method is effective and can effectively reduce the incidence of accidents caused by transfomer insulation faults.
作者
蔡怡然
CAI Yiran(Xiamen Zhuokong Technology Co.,Ltd., Xiamen 361006, China)
出处
《电工技术》
2019年第16期50-51,128,共3页
Electric Engineering
关键词
油浸式变压器
绝缘老化
状态评估
绝缘性能
oil immersed transformer
insulation aging
state evaluation
insulation performance