摘要
配电线路出现故障时,若采取线路停电作业法将对用户的供电可靠性造成一定的影响,而采用旁路不停电作业法对配电线路进行检修,可明显提高系统的供电可靠性。为此文章结合实例,对10kV配电网的旁路作业关键性技术的应用进行了分析。
When the distribution line fails, adopting the line overhaul with power interruption will have certain impact on the power supply reliability for users. However, the maintenance of the distribution line by the bypass working without power interruption can significantly improve the power supply reliability of the system. For this reason, combined with an example, the application of the key technology of the bypass working in 10 kV distribution network is analyzed.
作者
肖庆初
庞峰
郭瑞兵
龙凯
XIAO Qingchu;PANG Feng;GUO Ruibing;LONG Kai(Live Line Operation Branch of Yunnan Power Grid Co., Ltd., Kunming 650000, China;Yuxi Power Supply Bureau, Yuxi 653100, China)
出处
《电工技术》
2019年第16期66-67,70,共3页
Electric Engineering
关键词
配电网
旁路作业
不停电检修
供电可靠性
distribution network
bypass working
maintenance without power interruption
power supply reliability