发光二极管测量普朗克常量实验的改进 被引量:1

Improving Planck constant experiment using light emitting diode
下载PDF
导出
摘要 为了减小发光二极管测量普朗克常量实验中,二极管单色性和微小光强的判断对实验结果的影响,提出了利用单色仪判断二极管单色性优劣和利用光强探测器检测二极管刚导通时微小光强的改进方法.结果显示,使用改进后的方法测得的普朗克常量与标准值相对误差为1.24%,比改进前所得结果的准确值提高了80%. In order to overcome the difficulty in determining themonochromaticity and detecting the small light intensity oflight emittingdiode and reduce its influence on the experimental results in the Planck constant experiment,an improved method was proposed,which used monochromator todetermine the monochromaticity of the diode andlight intensity detector to detect the small light intensity of the diode when it was just turned on.The results showed that the measured Planck constant using this improved method had a relative error of 1.24%,which increased the accuracy with 80%.
作者 黎绮镟 黄威龙 LI Qi-xuan;HUANG Wei-long;ZHOU Bin(School of Physics and Telecommunications Engineering,South China Normal University,Guangzhou 510006,China;South China Institute of Advanced Optoelectronics,South China Normal University,Guangzhou 510006,China)
出处 《物理实验》 2019年第9期54-57,共4页 Physics Experimentation
基金 国家自然科学基金资助(No.61307053)
关键词 普朗克常量 发光二极管 单色性 微小光强 Planck constant light emitting diode monochromaticity small light intensity