摘要 以某厂350 MW机组脱硫氧化风机的运行方式为研究对象,监测2台和1台氧化风机运行时,脱硫吸收塔浆液的溶解氧质量浓度和机组负荷、烟气脱硫装置(FGD)入口SO2质量浓度和浆液pH值之间的关系。同时,选取溶解氧的质量浓度=1.5 mg/L作为吸收塔浆液得到充分氧化的标准,最终确定在不同负荷和不同FGD入口SO2质量浓度下,氧化风机的最佳运行方式。结果表明,通过氧化风机的运行优化,每年可节约厂用电1.1×10^6kW·h,对电厂脱硫系统的节能降耗与环保控制具有重要意义。 Taking the operation mode of a desulfurization and oxidation fans for a 350 MW unit as research object, by monitoring the operation mode within 2 oxidizing fans and 1 oxidizing fan,the relationships between the dissolved oxygen concentrationin of desulfurizing absorber slurry and the unit load, the SO2 concentration at FGD inlet and the pH of the slurry are obtained. At the same time,1.5 mg/L dissolved oxygen is selected as the standard line of full oxidation of slurry,which determines the optimum operation mode of the oxidizing fan at different loads and SO2 concentrations at the inlet of FGD.The results show that by optimizing the operation of the oxidizing fan, the power consumption for the plant can be saved by 1.1×10^6 kW·h every year. It is of great significance to the energy saving and environmental control of the desulfurization system in the power plant.
作者 赵林林 ZHAO Linlin(Huadian Tengzhou Xinyuan Thermal Power Company Limited, Tengzhou 277599, China)
出处 《华电技术》 CAS 2019年第9期45-48,52,共5页 HUADIAN TECHNOLOGY
关键词 氧化风机 脱硫 节能 溶解氧 SO2 oxidizing fan desulphurization energy saving dissolved oxygen SO2
  • 相关文献

参考文献3

二级参考文献23

  • 1胡满银,刘松涛,刘炳伟,汪黎东,王淑勤.湿式脱硫装置脱硫效率的回归分析[J].中国电力,2004,37(7):71-73. 被引量:11
  • 2龙辉,钟明慧.影响600MW机组湿法烟气脱硫装置厂用电率主要因素分析[J].中国电力,2006,39(2):74-77. 被引量:26
  • 3李文艳,王冀星,车建炜.湿法脱硫烟气湿排问题分析[J].中国电机工程学报,2007,27(14):36-40. 被引量:54
  • 4Jin D S,Deshwal B R,Park Y S. Simultaneous removal of SO2 and NO by wet scrubbing using aqueous chlorine dioxide solution[J].Journal of Hazardous Materials,2006,(1-3):412-417.
  • 5Nygaard H G,Kiil S,Johnsson J E. Full-scale measurements of SO2 gas phase concentrations and slurry compositions in a wet flue gas desulphurisation spray absorber[J].Fuel,2004,(09):1151-1164.doi:10.1016/j.fuel.2003.12.007.
  • 6Nolan P S,Redinger K E. Demonstration of additive use for enhanced mercury emissions control in wet FGD systems[J].Fuel Processing Technology,2004,(85):587-600.
  • 7Graus W H J,Worrel E. Effects of SO2 and NOx control on energy-efficiency power generation[J].Energy Policy,2007,(35):3898-3908.
  • 8曾庭华;杨华.湿法烟气脱硫系统的安全性及优化[M]北京:中国电力出版社,2005126.
  • 9曾庭华;杨华.湿法烟气脱硫系统的调试、试验及运行[M]北京:中国电力出版社,200816.
  • 10安连锁.泵与风机[M]北京:中国电力出版社,2001220.

共引文献123

同被引文献123

引证文献11

二级引证文献56

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部