期刊文献+

基于数值计算的地源热泵系统热平衡控制策略 被引量:1

Thermal Balance Control Strategy of Ground Source Heat Pump System Based on Numerical Calculation
下载PDF
导出
摘要 对拥有云数据管控平台的复合式地源热泵系统的热平衡控制策略进行了研究。对使用地源热泵系统的某小区采用eQuest软件模拟建筑全年逐时负荷。在逐时负荷下,通过MATLAB软件计算机组的逐时功率并得到热泵机组的逐时释热量和吸热量,进而确定一个负荷参数值k。对于夏热冬冷地区,当系统夏季逐时负荷达到k时开启热泵机组或冷水机组,使这个基于k值的控制策略可以使地源热泵系统对岩土层的释热量和吸热量达到动态平衡的效果。在TRNSYS平台上模拟运行地源热泵系统,比较新旧热平衡控制策略的优劣。 This paper studies the thermal balance control strategy of a hybrid ground source heat pump system with a cloud data control platform.eQuest software was used to simulate the year-round hourly load of a residential area using ground source heat pump system.The hourly power is calculated by MATLAB software and a parameter value k is determined.For hot summer and cold winter areas,the heat pump unit or water cooling unit will be opened when the system’s hourly load reaches k in summer,so that the k-value based control strategy can achieve the dynamic balance of heat release and heat absorption of the ground source heat pump system to the geotechnical layer.The ground source heat pump system is simulated on TRNSYS platform,and the old and new thermal balance control strategies are compared.
作者 罗丞朝 曹勇 柳靖 张亮 LUO Cheng-chao;CAO Yong;LIU Jing;ZHANG Liang(University of Science and Technology Beijing,Beijing 100083,China;China Academy of Building Research,Beijing 100013,China;China Gezhouba Group Real Estate Development Co.,Ltd.,Beijing 100000,China)
出处 《建筑节能》 CAS 2019年第9期22-25,共4页 BUILDING ENERGY EFFICIENCY
基金 “十三五”国家重点研发计划项目“公共机构高效用能系统及智能调控技术研发与示范”(2016YFB0601700)
关键词 复合式地源热泵系统 热平衡控制策略 岩土层释热量 岩土层吸热量 hybrid ground source heat pump thermal balance control strategy heat released to the geotechnical layer heat absorbed from the geotechnical layer
  • 相关文献

参考文献5

二级参考文献25

  • 1杨卫波,施明恒.混合地源热泵系统(HGSHPS)的研究[J].建筑热能通风空调,2006,25(3):20-26. 被引量:37
  • 2汪训昌.关于发展地源热泵系统的若干思考[J].暖通空调,2007,37(3):38-43. 被引量:55
  • 3王华军,赵军.混合式地源热泵系统的运行控制策略研究[J].暖通空调,2007,37(9):131-134. 被引量:29
  • 4Stephen P K. A design method for hybrid ground-source heat pumps[J]. ASHRAE Transactions, 1998,104(2):691-698.
  • 5Yavuzturk C, J D S. Comparative study to investigate operating and control strategies for hybrid ground source heat pump systems using a short time step simulation model[J]. ASHRAE Transactions, 2000,106(2):192-209.
  • 6Yi Man, Yang Hongxing, Wang Jinggang. Study on hybrid ground-coupled heat pump system for air- conditioning in hot-weather areas like HongKong[J]. Applied Energy, 2010,87(9):2826-2833.
  • 7ASHRAE Handbook-HVAC Systems and Equipment[M]. Atlanta:American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  • 8MICHOPOULOS A,BOZIS D,KIKIDIS P,et al.Three-years operation experience of a ground source heat pump system in northern Greece[J].Energy and Buildings,2007,39(3):328-334.
  • 9YU X,WANG R Z,ZHAI X Q.Year round experimental study on a constant temperature and humidity air-conditioning system driven by ground source heat pump[J].Energy,2011,36(2):1309-1318.
  • 10LI S H,YANG W H,ZHANG X S.Soil temperature distribution around a U-tube heat exchanger in a multi-function ground source heat pump system[J].Applied Thermal Engineering,2009,29(17):3679-3686.

共引文献139

同被引文献11

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部