期刊文献+

Smart Semi-active PID-ACO control strategy for tower vibration reduction in Wind Turbines with MR damper 被引量:2

Smart Semi-active PID-ACO control strategy for tower vibration reduction in Wind Turbines with MR damper
下载PDF
导出
摘要 Wind turbine technology is well known around the globe as an eco-friendly and eff ective renewable power source. However, this technology often faces reliability problems due to structural vibration. This study proposes a smart semi-active vibration control system using Magnetorheological (MR) dampers where feedback controllers are optimized with nature-inspired algorithms. Proportional integral derivative (PID) and Proportional integral (PI) controllers are designed to achieve the optimal desired force and current input for MR the damper. PID control parameters are optimized using an Ant colony optimization (ACO) algorithm. The eff ectiveness of the ACO algorithm is validated by comparing its performance with Ziegler-Nichols (Z-N) and particle swarm optimization (PSO). The placement of the MR damper on the tower is also investigated to ensure structural balance and optimal desired force from the MR damper. The simulation results show that the proposed semi-active PID-ACO control strategy can signifi cantly reduce vibration on the wind turbine tower under diff erent frequencies (i.e., 67%, 73%, 79% and 34.4% at 2 Hz, 3 Hz, 4.6 Hz and 6 Hz, respectively) and amplitudes (i.e. 50%, 58% and 67% for 50 N, 80 N, and 100 N, respectively). In this study, the simulation model is validated with an experimental study in terms of natural frequency, mode shape and uncontrolled response at the 1st mode. The proposed PID-ACO control strategy and optimal MR damper position is also implemented on a lab-scaled wind turbine tower model. The results show that the vibration reduction rate is 66% and 73% in the experimental and simulation study, respectively, at the 1st mode. Wind turbine technology is well known around the globe as an eco-friendly and effective renewable power source. However, this technology often faces reliability problems due to structural vibration. This study proposes a smart semi-active vibration control system using Magnetorheological(MR) dampers where feedback controllers are optimized with nature-inspired algorithms. Proportional integral derivative(PID) and Proportional integral(PI) controllers are designed to achieve the optimal desired force and current input for MR the damper. PID control parameters are optimized using an Ant colony optimization(ACO) algorithm. The effectiveness of the ACO algorithm is validated by comparing its performance with Ziegler-Nichols(Z-N) and particle swarm optimization(PSO). The placement of the MR damper on the tower is also investigated to ensure structural balance and optimal desired force from the MR damper. The simulation results show that the proposed semi-active PID-ACO control strategy can significantly reduce vibration on the wind turbine tower under different frequencies(i.e., 67%, 73%, 79% and 34.4% at 2 Hz, 3 Hz, 4.6 Hz and 6 Hz, respectively) and amplitudes(i.e. 50%, 58% and 67% for 50 N, 80 N, and 100 N, respectively). In this study, the simulation model is validated with an experimental study in terms of natural frequency, mode shape and uncontrolled response at the 1 st mode. The proposed PID-ACO control strategy and optimal MR damper position is also implemented on a lab-scaled wind turbine tower model. The results show that the vibration reduction rate is 66% and 73% in the experimental and simulation study, respectively, at the 1st mode.
出处 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2019年第4期887-902,共16页 地震工程与工程振动(英文刊)
基金 University of Malaya Research under Grant No.RP013B-15SUS,Postgraduate Research Fund(PG098-2015A)
关键词 ant COLONY optimization fi nite diff erence method MAGNETORHEOLOGICAL damper PID-ACO controller semiactive control system identifi cation wind turbine TOWER ant colony optimization finite difference method magnetorheological damper PID-ACO controller semiactive control system identification wind turbine tower
  • 相关文献

参考文献6

二级参考文献41

  • 1S.D.Bhart,S.M.Dumne,M.K.Shrimali.Earthquake response of asymmetric building with MR damper[J].Earthquake Engineering and Engineering Vibration,2014,13(2):305-316. 被引量:3
  • 2李德源,叶枝全,陈严.风力机旋转叶片的多体动力学数值分析[J].太阳能学报,2005,26(4):473-481. 被引量:30
  • 3陆鸣,田学民,王笃国,李丽媛.建筑结构基础隔震技术的研究和应用[J].震灾防御技术,2006,1(1):31-38. 被引量:19
  • 4周福霖,谭平,冼巧玲,黄襄云,杨铮.房屋隔震体系的研究与应用(英文)[J].建筑科学与工程学报,2006,23(2):1-8. 被引量:18
  • 5Soong TT,Dargush GF.Passive Energy dissipation Systems in Structural Engineering. Journal of Women s Health . 1997
  • 6Fabio Casciati,José Rodellar,Umut Yildirim.Active and semi-active control of structures – theory and applications: A review of recent advances[J]. Journal of Intelligent Material Systems and Structures . 2012 (11)
  • 7ArturoRodríguez,FrancescPozo,ArashBahar,LeonardoAcho,YolandaVidal,JoséRodellar.Force‐derivative feedback semi‐active control of base‐isolated buildings using large‐scale MR fluid dampers[J]. Struct. Control Health Monit. . 2012 (1)
  • 8Arash Bahar,Francesc Pozo,Leonardo Acho,José Rodellar,Alex Barbat.Hierarchical semi-active control of base-isolated structures using a new inverse model of magnetorheological dampers[J]. Computers and Structures . 2010 (7)
  • 9N. Aguirre,F. Ikhouane,J. Rodellar.Proportional-plus-integral semiactive control using magnetorheological dampers[J]. Journal of Sound and Vibration . 2010 (10)
  • 10M.Zapateiro,H. R.Karimi,N.Luo,B. F.Spencer.Real‐time hybrid testing of semiactive control strategies for vibration reduction in a structure with MR damper[J]. Struct. Control Health Monit. . 2010 (4)

共引文献35