摘要
广州市环境监测站在2017年12月—2018年1月完成了PM1冬季比对试验工作,验证了PM1连续自动采样的可行性,同时了解了重点区域环境空气PM1浓度水平、分布区间等相关规律。
The China National Environmental Monitoring Centre started the pilot monitoring of PM 1.in ambient air in 2017.Guangzhou Environmental Monitoring Centre participated in the pilot monitoring work as a cooperative unit.Meanwhile the opportunity was given to conduct a preliminary comparative study in order to verify the feasibility of continuous automatic sampling of PM 1 and the relevant laws of PM 1 concentration level and distribution range in key areas at the same time.
作者
洪达驰
张金谱
裴成磊
梁永健
HONG Da-chi;ZHANG Jin-pu;PEI Cheng-lei;LIANG Yong-jian(Guangzhou Environmental Monitoring Center,Guangzhou Guangdong 511400,China)
出处
《环境科学导刊》
2019年第6期51-57,共7页
Environmental Science Survey
关键词
PM1
重量法
手工采样
比对试验
冬季
广州市
PM1
gravimetric method
manual sampling
comparison test
winter
Guangzhou