期刊文献+

达克罗宁用于经口电子软镜引导下清醒气管插管效果观察 被引量:3

Effect of dyclonineon awake intubation under the guidance of electronic soft endoscopy
下载PDF
导出
摘要 目的研究达克罗宁用于经口电子软镜引导下清醒气管插管应激反应的影响。方法将术前评估存在困难气道的患者60例,ASAⅠ~Ⅲ级,年龄45~72岁,随机分成两组。两组于操作前均给予阿托品0.5mg,持续泵注右美托咪定0.5μg/(kg?h),表面麻醉前均用2%利多卡因3ml行环甲膜穿刺。对照组(A组)用1%丁卡因表面麻醉,实验组(B组)用达克罗宁胶浆含漱,观察比较两组患者入室(T1)、表面麻醉5min后(T2)、电子软镜置入时(T3)、插管完成后(T4)、插管完成后5min(T5)的HR、SBP/DBP。记录置入电子软镜到插管完成所用时间(T0)以及患者术后随访咽痛和声音嘶哑的例数。结果两组均顺利完成气管插管,与A组比较,B组T2~T4HR、SBP/DBP波动较小(P<0.05),插管所用时间优于A组(P<0.05)。术后随访B组不良反应发生率明显低于A组(P<0.05)。结论达克罗宁胶浆表面麻醉用于经口电子软镜引导下清醒插管能有效降低患者的应激反应,缩短插管时间,维持血流动力学稳定,降低术后不良反应发生率。 Objective To study the effect of dyclonine on stress response of conscious tracheal intubation under the guidance of electronic soft microscope. Methods 60 patients (ASA I-III grade 45-72 years old) with difficult airway were randomly divided into two groups. The two groups were given atropine 0.5 mg before operation, and dexmetomidine 0.5 μg/(kg?g) by continuous pump. 2% lidocaine 3 ml was used for thyrocricocentesis before superficial anesthesia. The control group (group A) was treated with 1% tetracaine superficial anesthesia, and the experimental group (group B) was gargled with dyclonine glue. Observation and comparison of two groups of patients of HR and SBP/DBP at entering the operation room (T1), topical anesthesia 5 min later (T2), electronic soft mirror placement (T3), after the intubation is complete (T4), intubation 5 min later (T5). Record the time taken to complete the intubation (T0) and the number of cases of postoperative follow-up of pharynx pain and hoarseness. Results The tracheal intubation was completed successfully in both groups. Compared with group A, the fluctuation of T2-T4 HR, SBP/DBP in group B was smaller (P<0. 05), and the intubation time was better than that in group A (P<0. 05). The incidence of adverse reactions in group B was significantly lower than that in group A after follow-up. Conclusion Dyclonine glue can effectively reduce stress response, shorten intubation time, maintain hemodynamic stability and reduce the incidence of postoperative adverse reactions in patients with conscious intubation under the guidance of electronic soft endoscope, awake intubation.
作者 庄渊钊 王一雄 颜景佳 吴竑鹏 Zhuang Yuanzhao;Wang Yixiong;Yan Jingjia;Wu Hongpeng(Department ofAnesthesiology, the First Hospital of QuanzhouAffiliate to Fujian Medical University,Quanzhou, Fujian, 362000, China)
出处 《当代医学》 2019年第29期76-78,共3页 Contemporary Medicine
关键词 达克罗宁 电子软镜 清醒插管 Dyclonine Electronic soft endoscopy Awake intubation
  • 相关文献

参考文献2

二级参考文献12

  • 1丛寿耆,常林宝,王汉川,吕进,季永兰,张勤功,李增艳,王根才,李树鹏.利多卡因对气管内插管时心血管副反应效果的观察[J].肿瘤研究与临床,1995,7(1):24-25. 被引量:1
  • 2张海山,高秀琴.芬氟合剂预防气管插管时的心血管反应及琥珀胆碱引起的肌颤[J].佳木斯医学院学报,1996,19(5):80-81. 被引量:3
  • 3邓硕曾.麻醉需降低病人应激反应[J].临床麻醉学杂志,1996,12:30-30.
  • 4[3]James MFM,Beer RE and Esser JD.Intravenous magnesium sugfate inhits catocholamine release associatod with tracheal intabation[J].Anesth Analg,1989,68(6):772.
  • 5[4]Drbyshine D R,Chmielewski A,Fell D,et al.Plasma catecholamine responses to tracheal intubation[J].Br J Anesth,1983,55(1):85.
  • 6[5]Tse JC,Rimm EB,Efarcs AH.Predlcting difficult endotrachbsl intubation in surgical patients scheduled for general anesthesia:a prospective blind audy[J].Anegh Analg,1995,81(2):254.
  • 7[6]Rusell W J.Changes in plasma catecholamine concentration during endotrachenl intubation[J].Brit J Anaesth,1981,53(8):837.
  • 8[7]King BD.Reflex circulatory responses to direct laryngoscopy and traehenl intubation performed during general anesthesia[J].Anaesthesology,1951,12(4):556.
  • 9[8]James MFM,Beer RE and Esser JD.Intravenous magnesium sulfate inhlts catecholamine release associated with tracheal intubation[J].Anesth Analg,1989,68(6):772.
  • 10[9]Derbyshine DR,Chmielewski A,Fell D,et al.Plasma catecholamine responsea to tracheal intubation[J].Br J Aneath,1983,55(8):855.

共引文献118

同被引文献38

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部