期刊文献+

免疫克隆算法在500kV输电线路故障识别中的应用 被引量:5

Application of Immune Clone Algorithm to Fault Identification of 500 kV Transmission Lines
下载PDF
导出
摘要 500kV输电线路是我国广泛使用的高压输电线路,对其故障类型识别进行研究具有重要意义。针对现有的免疫克隆算法提出变异算子双重优化的思路,并将优化后的免疫克隆算法用于解决500kV输电线路的故障识别。对方法的有效性和准确性进行了仿真验证,验证结果表明能更准确、快速地识别线路故障,且有较好的可移植性,可以为其他等级的高压输电线路的故障识别提供参考。 For 500 kV high-voltage transmission lines widely used in China,research on their fault type identification is of great importance.In view of the existing immune clone algorithm,this paper introduced the idea of dual optimization of mutation operator,and applied the optimized immune clone algorithm to solve the problem of fault identification of 500 kV transmission lines.Simulation verification was completed on the validity and accuracy of the proposed approach,and verification results indicated that the proposed approach could identify line faults accurately and quickly.Furthermore,it had a good portability and could provide ideas for the solution of the problem of fault identification for other levels of high-voltage transmission lines.
作者 孔德健 史其宁 白佳琦 吕轩 王金玉 Kong Dejian;Shi Qining;Bai Jiaqi;Lyu Xuan;Wang Jinyu(State Grid Jibei Electric Power Co.,Ltd.,Maintenance Branch,Beijing 102488,China;College of Electrical Engineering and Information,Northeast Petroleum University, Daqing Heilongjiang 163318,China)
出处 《电气自动化》 2019年第5期38-40,102,共4页 Electrical Automation
关键词 500KV输电线路 故障识别 免疫克隆算法 变异算子双重优化 仿真分析 500 kV transmission line fault identification immune clone algorithm dual optimization of mutation operator simulation analysis