期刊文献+

考虑牵引网参数对城轨再生制动能量回馈装置输出谐波与谐振峰值的影响 被引量:1

Impacts of Traction Network Parameters on Harmonics and Resonance Peak Value of Regenerative Braking Energy Feedback Device
下载PDF
导出
摘要 滤波器的选型对变流器输出谐波的影响至关重要,文章以城轨再生制动能量回馈系统为研究对象,研究LCL滤波器与LC滤波器的滤波效果。同时,考虑牵引网络参数对城轨再生制动能量回馈装置输出谐波和谐振峰值的影响,采用一种基于比例环节的虚拟电阻串电容法用来消除谐振峰值,增强系统稳定性。研究结果表明,所采用的虚拟阻尼方法在工程应用上不失为一种可行的方法。 The selection of filter is very important to the harmonic output of converter. Taking the regenerative braking energy feedback system of urban rail as the research object, the filtering effect of LCL filter and LC filter was studied. At the same time, considering the influence of traction network parameters on the output harmonic and resonance peak value of regenerative braking energy feedback device, a virtual resistance series capacitance method based on proportional link was adopted to eliminate the resonance peak value and enhance the system stability. The results showed that the virtual damping method is feasible in engineering application.
作者 胡家喜 何亚屏 曹佳 成正林 HU Jiaxi;HE Yaping;CAO Jia;CHENG Zhenglin(Zhuzhou CRRC Times Electric Co., Ltd., Zhuzhou, Hunan 412001, China)
出处 《机车电传动》 北大核心 2019年第5期91-94,143,共5页 Electric Drive for Locomotives
关键词 LCL滤波器 再生制动能量回馈系统 牵引网络参数 比例环节 虚拟电阻串电容 仿真 LCL filter regenerative braking energy feedback system traction network parameters proportional link virtual resistance series capacitance simulation
  • 相关文献

参考文献5

二级参考文献190

  • 1白志红,阮新波,徐林.基于LCL滤波器的并网逆变器的控制策略[J].电工技术学报,2011,26(S1):118-124. 被引量:29
  • 2武健,徐殿国,何娜.并联有源滤波器输出LCL滤波器研究[J].电力自动化设备,2007,27(1):17-20. 被引量:42
  • 3许洪华.中国光伏发电技术发展研究(英文)[J].电网技术,2007,31(20):77-81. 被引量:79
  • 4Majid P, Pritam D, JosefD, et al. A new control approach based on the differential flatness theory for an AC/DC converter used in electric vehicles[J]. IEEE Transactions on PowerElectronics, 2012, 27(4): 2085-2103.
  • 5Omar H, Joeri V M, Philippe L. Control and analysis of an integrated bidirectional DC/AC and DC/DC converters for plug-in hybrid electric vehicle applications[J]. Journal of Power Electronics, 2011, 11(4): 408-417.
  • 6Kim D E, Lee D C. Feedback lineafization control of grid-interactive PWM converters with LCL filters [J]. Journal of Power Electronics, 2009, 9(2): 288-299.
  • 7Michael H B, Wilhelm F F. Active damping for three-phase PWM rectifiers with high-order line-side filters[J]. IEEE Transactions on Industrial Electronics, 2009, 56(2): 371-379.
  • 8He Jinwei, Li Yunwei. Generalized closed-loop control schemes with embedded virtual impedances for voltage source converters with LC or LCL filters[J]. IEEE Transactions on Power Electronics, 2012, 27(4): 1850-1861.
  • 9Liu Fei, Zha Xiaoming, Zhou Yan, et al. Design and research on parameter of LCL filter in three-phase grid-connected inverter [C]//IEEE International Power Electronics and Motion Control Conference. Wuhan.. IEEE, 2009: 1224-1227.
  • 10Park M Y, Chi M H, Park J H, et al. LCL-filter design for grid-connected PCS using total harmonic distortion and ripple attenuation factor[C]//The 2010 International Power Electronics Conference. Sapporo: CIGRE, 2010: 1688-1694.