摘要
梁子湖水源水夏季藻类污染严重,常规饮水处理工艺效果不佳。为提高常规工艺的出水水质,本实验在常规工艺前增加了紫外/过硫酸盐(UV/PS)预氧化措施。结果表明:UV/PS体系具有良好的预处理效果,最终出水浊度、叶绿素a和UV254的平均去除率在常规处理的基础上分别提升了9.96%、17.93%和12.60%;同时UV/PS预处理不会对出水pH、碱度、硬度、DOC、总铝等指标产生较大影响。
Conventional water treatment process is ineffective due to algae pollution in Liangzi Lake.To improve the water quality of the conventional process,UV/Persulfate(UV/PS)was used as the peroxidation process in this experiment.Results showed that UV/PS system was an excellent pretreatment process,It makes the final average removal rate of turbidity,chlorophyll a and UV254 raise by 9.96%、17.93%and 12.60%,respectively and wouldn’t have significant impacts on the water pH,alkalinity,hardness,DOC,total aluminum and other indicators.
作者
熊斌
邬长友
王晶文
万颖
王宗平
谢鹏超
XIONG Bin;WU Changyou;WANG Jingwen;WAN Ying;WANG Zongping;XIE Pengchao(School of Environmental Science and Engineering,Huazhong University of Science and Technology,Wuhan 430074,China)
出处
《水处理技术》
CAS
CSCD
北大核心
2019年第10期86-90,共5页
Technology of Water Treatment
基金
国家自然科学基金(51578259)
关键词
紫外/过硫酸盐
预处理
中试
混凝沉淀
ultraviolet/persulfate(UV/PS)
pretreatment
pilot test
coagulation-sedimentation