摘要
利用武鸣自动土壤水分站站址迁移后,其土壤体积含水量的人工对比测量值与土壤体积含水量自动站观测数据通过对比分析,结合对武鸣自动土壤水分站站址搬迁的选址的分析研究,找出2017年武鸣土壤水分观测站未通过检验而无法投入业务使用的原因。分析结果对自动土壤水分站站址的选址起到一定的借鉴作用,为其他需迁移或新建土壤水分站的部门提供参考。
The artificial contrast measurement value of soil volumetric water content after migration of Wuming automatic soil moisture station site was compared with soil volume water content measurement,and the site selection of Wuming automatic soil moisture station site relocation was analyzed in order to find out why the Wuming soil moisture observatory failed to pass the test and could not be put into business use in 2017.The research can be used as a reference for the site selection of automatic soil moisture stations for other departments who need to migrate or build new soil moisture stations.
作者
黄曼贞
韦慧艳
Huang Manzhen;Wei Huiyan(Wuming District Meteorological Bureau of Nanning,Nanning Guangxi 530100)
出处
《气象研究与应用》
2019年第3期102-105,共4页
Journal of Meteorological Research and Application
基金
广西科技重点研发计划项目(桂科AB17195037)
关键词
自动土壤水分站
搬迁
数据分析
借鉴
automatic soil moisture station
relocation
data analysis
reference