某通讯塔桩身缺陷的检测判定与原因分析 被引量:1

The detection judgment and cause analysis on the pile defects of a communication tower
下载PDF
导出
摘要 通过对某塔基桩身混凝土完整性检测,判定其存在离析和断桩等质量缺陷。依据芯样离析特征,结合地质条件分析和抽水影响半径计算,推定是因管井抽水造成的质量事故。 Through the integrity test of pile body concrete of a tower foundation,judged that there were quality defects such as segregation and broken pile,according to the core segregation characteristics,combining with the geological conditions made analysis and pumping influence radius calculation,presumped the quality accident was caused by tube well pumping.
作者 马驰 Ma Chi(Jiangsu Second Geological Engineering Investigation Institute,Xuzhou 221000,China)
出处 《山西建筑》 2019年第18期78-79,共2页 Shanxi Architecture
关键词 钻孔灌注桩 基桩检测 质量缺陷 管井 bored pile foundation pile detection quality defects tube well
  • 相关文献

参考文献2

二级参考文献5

  • 1任春山,荆志东.基桩完整性检测技术问题的探讨[J].铁道工程学报,2007,24(S1):330-333. 被引量:4
  • 2TB10218-2008,铁路工程基桩检测技术规程[S].
  • 3JGJ106-2003.建筑基桩检测技术规范[S].[S].,..
  • 4TB 10218-99,铁路工程基桩无损检测规程[S].
  • 5Karaoguz Meric, Bilgutay Nihat, Akgul Tayfun, etc. Ultrasonic Testing of Concrete Using Split Spectrum Processing. Materials Evaluation[J].American Society for Nondestructive Testing, 1999 ( 11 ) : 1183 - 1190.