摘要
本文介绍了电梯中制动器失效后产生的事故类型和制动器的动作原理,并分析了检规中关于制动器的要求:电梯制动器必须有两个独立的电气装置来检测。结合检规要求分析了检验中的一则案例,案例中将两个独立电气装置切除一个从而产生安全隐患。
This paper introduces the types of accidents caused by brake failure in elevator and the action principle of brake,and analyses the requirements of the inspection regulations on brake:the elevator brake must have two independent electrical devices to detect.According to the requirements of inspection regulations,a case in the inspection is analyzed.In the case,two independent electrical devices are removed from one to create potential safety hazards.
作者
蔡思杰
Cai Sijie(Fujian Special Equipment Inspection and Research InstituteFujianQuanzhou362000)
出处
《科技风》
2019年第30期194-194,共1页
关键词
无机房
故障
应急救援
inorganic room
failure
emergency rescue