根据喷淋管布置支撑条件及FRP管道设计相关标准规范对喷淋管道设计方法进行了讨论,对FRP喷淋管的设计提出了采用有限元分析的方法。设计中对安全系数的选取进行了说明,确定了FRP喷淋管的设计强度和刚度条件的量化指标。
The design method of spraying pipe is discussed according to the support condition and the relevant standard code of FRP pipe design.The finite element analysis method is proposed for the design of FRP spraying pipe. The selection of safety factor is explained in the design,and the quantitative index of design strength and stiffness condition of FRP spraying pipe is determined.
作者
杨秀杰
Yang Xiujie(Datang Environment Industry Group Co.,Ltd.,Beijing 100097,China)
出处
《山西建筑》
2019年第19期32-34,共3页
Shanxi Architecture
关键词
喷淋管
FRP
有限元分析
spraying pipe
FRP
finite element analysis