谈10000 m^3钢筋混凝土拱顶罐渗漏的原因及补救措施

Discuss on the causes and remedial measures of leakage of 10 000 m^3 reinforced concrete dome-roof tank
下载PDF
导出
摘要 介绍了某实训基地10 000 m^3拱顶罐的工程施工过程中出现的问题,结合施工质量控制,对其原因进行深入剖析,制定预防对策防止该事故再次发生,并针对存在的问题提出补救对策,通过一系列的措施,保证建设合格工程。 This paper is related to the quality control of construction and combined with the problems in the construction of 10 000 m^3 dome-roof tank in a training base,the causes of these problems are deeply analyzed,and preventive measures are developed to prevent the accident from happening again,at the same time,remedial measures are put forward to solve the existing problems,and a series of measures are taken to ensure the construction of qualified.
作者 孟晓飞 程振华 张卫国 郑忠原 郝副良 Meng Xiaofei;Cheng Zhenhua;Zhang Weiguo;Zheng Zhongyuan;Hao Fuliang(Sinopec Petroleum Engineering Zhongyuan Corporation,Puyang 4570011,China)
出处 《山西建筑》 2019年第19期74-75,共2页 Shanxi Architecture
关键词 混凝土水罐 渗漏原因 防治措施 concrete water tank causes of leakage remedial measures