期刊文献+

110kV输变电工程绝缘配置设计

Insulation Configuration Design of 110 kV Transmission and Substation Project
下载PDF
导出
摘要 在高压输电线路中,绝缘子型式的选择及绝缘配置对线路的安全运行起着至关重要的作用,对高压输电线路的工程设计也有非常直接的影响。从一个实际的110kV高压输电线路工程的绝缘配置来探讨在高压输电工程中污区的确定和绝缘子类型的选择以及绝缘配置的情况,以确定最优的绝缘配置方案,来确保线路运行的安全性。 In high voltage transmission lines, the selection of insulator type and insulation configuration play a crucial role in the safe operation of the lines and will directly affect the design results of high voltage transmission lines. Based on a practical 110KV high-voltage transmission line insulation configuration, this paper discusses the determination of pollution area, selection of insulator type and insulation configuration in high-voltage transmission line, so as to determine the optimal insulation configuration scheme and ensure the safety of line operation.
作者 陈静 CHEN Jing(Department of Electrical and Mechanical Engineering, Huaibei Vocational and Technical College, Huaibei Anhui 235000,China)
出处 《佳木斯大学学报(自然科学版)》 CAS 2019年第5期729-732,共4页 Journal of Jiamusi University:Natural Science Edition
基金 安徽省高校质量工程项目(2014jxtd063) 安徽省高校质量工程教学研究项目(2016jyxm0939)阶段性成果
关键词 输电线路 绝缘子 绝缘配置 污区 110kV transmission line electrical insulator insulation configuration unclean area 110kV
  • 相关文献

参考文献4

二级参考文献26

  • 1陈秀娟,丁玉剑,朱艺颖.±800kV直流输电线路过电压、防雷及绝缘配合差异化设计研究[R].北京:中国电力科学研究院,2014.
  • 2丁玉剑,于听哲,朱艺颖,等,哈密-郑州±800kV直流线路过电压和绝缘设计深化研究[R].北京:中国电力科学研究院,2012.
  • 3葛栋,丁玉剑,朱艺颖,等.溪洛渡-浙西±800kV直流线路过电压和绝缘配合设计深化研究[R].北京:中国电力科学研究院,2012.
  • 4International Electrotechincal Commission. IEC 60071-1:2006 Insula- tion coordination, part 1: definitions, principles and rules[S], 2006.
  • 5International Electrotechincal Commission. IEC 60071-2:1996 Insula- tion co-ordination, part 2: application guide[S], 1996.
  • 6IEEE Std 1862TM-2014 IEEE recommended practice for overvoltage and insulation coordination of transmission systems at 1 000 kV AC and above[S], 2014.
  • 7International Electrotechincal Commission. IEC 60071-5:2002 Proce- dures for high-voltage direct current(HVDC) converter stations[S], 2002.
  • 8GB/T311.3-2007绝缘配合第3部分:高压直流换流站绝缘配合程序[S],2007.
  • 9Q/GDW144-2006 ±800kV特高压直流换流站过电压保护和绝缘配合导则[S].北京:中国电力出版社,2006.
  • 10吕金壮,赵杰.云广±800kV直流输电系统过电压与绝缘配合研究[J].南方电网技术,2009,3(2):18-22. 被引量:25