摘要 福州市琴亭河黑臭水体治理中,针对大水量、短期内难溯源实现清污分离的暗涵出水,采用磁混凝-FBSC(固定床生物海绵填料工艺)组合工艺进行分散式处理,处理后的尾水直接补充河道,达到活水提质的目的。该工艺投产运行后,COD、BOD5和氨氮去除率分别达到71.4%、81.1%和95.2%,出水主要水质指标稳定达到《地表水环境质量标准》(GB 3838-2002)地表Ⅴ类标准。 The combined process of magnetic coagulation and FBSC(Fixed bed bio-sponge carries) was adopted in dispersive treatment of the hidden culvert effluent which is massive and difficult to find source on the black-odorous water-Qinting River. The treated water was discharged into the river directly to improve the quality of live water. After operation,the removal rates of COD, BOD5 and ammonia nitrogen achieved 71.4%, 81.1% and 95.2% respectively. The main indexes of the treated water could met level Ⅴ stipulated in Environmental quality standards of surface water(GB 3838-2002).
作者 王卓艺 李枞林 程林波 汪诚文 张鸿涛 黄守斌 阎敏 牛慧玲 Wang Zhuoyi;Li Conglin;Cheng Linbo;Wang Chengwen;Zhang Hongtao;Huang Shoubin;Yan Min;Niu Huiling(Beijing Guohuan Tsinghua Environmental Engineering Design andResearch Institute Co., Ltd., Beijing 100084 , China)
出处 《给水排水》 CSCD 北大核心 2019年第10期57-60,共4页 Water & Wastewater Engineering
关键词 磁混凝 FBSC生化工艺 城市黑臭水体治理 Magnetic coagulation FBSC process Treatment of urban black and odorous water