摘要 南山污水处理厂位于深圳市核心区域前海片区,现状总规模为73. 6×10^4m^3/d(其中防洪应急一级处理规模为17. 6×10^4m^3/d),生化系统规模为56×10^4m^3/d,采用MUCT工艺,出水水质执行一级B排放标准。为解决现状处理工艺对总氮、总磷等处理效果较差的问题,将现状MUCT工艺改造为曝气缺氧+多级AO工艺,同时在二沉池后增设加砂高密度沉淀池。项目改造后生产运行稳定,效果良好,能耗低,出水水质全面优于《城镇污水处理厂污染物排放标准》(GB18918-2002)一级A标准。 Nanshan sewage treatment plant was located in Qianhai District,the core area of Shenzhen City. The total scale of the present situation was 73. 6 × 10^4 m^3/d( of which 17. 6 × 10^4 m^3/d was the primary treatment of flood control emergency). The biological treatment process had a scale of 56 × 10^4 m^3/d. MUCT technology was adopted and the first class B effluent standard could be met. In order to solve the problem that the poor performance of the current treatment process had on total nitrogen and total phosphorus removal,the current MUCT process was transformed into the aeration anoxia + multistage AO process,and a sand-adding high-density sedimentation tank was added after the secondary sedimentation tank. After the project transformation,the operation performance was stable,the effect was good,the energy consumption was low,and the effluent quality was better than first class A standard of Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant( GB 18918-2002).
作者 戴仲怡 王雪 彭建国 刘文彬 李华 DAI Zhong-yi;WANG Xue;PENG Jian-guo;LIU Wen-bin;LI Hua(Central and Southern China Municipal Engineering Design & Research Institute Co. Ltd.,Wuhan 430010,China;Shenzhen Water < Group > Co. Ltd.,Shenzhen 518000,China)
出处 《中国给水排水》 CAS CSCD 北大核心 2019年第18期50-54,共5页 China Water & Wastewater
关键词 曝气缺氧 短程反硝化 多段AO 精确曝气 aeration anoxia shortcut denitrification multi-stage AO precision aeration
  • 相关文献

参考文献2

二级参考文献29

共引文献30

同被引文献91

引证文献7

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部