摘要 漏损问题是当今社会的热点问题,为了使漏损定位更加快速、科学,对供水管网流量数据进行了统计分析。通过供水管网中的流量监测点,能够得到大量的流量数据,以此为基础,分别研究了 t检验分析法和均值差分析法应用在漏损定位中的可行性与准确性,并对这两种方法进行从无漏点到单漏点、从无漏点到多漏点、从少漏点到多漏点、等多种情况的比较分析,为水司进行供水管网漏损管理提供新思路。结果表明,两种方法均能较为准确地定位漏损,其中均值差分析定位漏损时干扰较少,t检验分析则能够充分利用每个数据。 The leakage problem of water supply network is hot in modem society. In order to locate leakage more quickly and scientifically, the flow data of water supply network were analyzed. A large amount of flow data can be obtained through the flow monitoring points in water supply network. On this basis, the application of mean difference test and student' s t test in leakage location was introduced, and the two methods were compared from no leakage to single leakage, no leakage to multiple leakages, and few leakages to multiple leakages. The results showed that both methods could locate the leakage accurately, and the mean difference test had less interference when locating the leakage. The student's t test could make full use of each data.
作者 杜建军 胡诗苑 高金良 张鑫 杨浩 DU Jian-jun;HU Shi-yuan;GAO Jin-liang;ZHANG Xin;YANG Hao(Hami Tuoshi Water Conservancy and Hydropower Survey and Design Co. Ltd.,Hami 839000,China;School of Environment,Harbin Institute of Technology,Harbin 150090,China;College of Civil and Architectural Engineering,Heilongjiang Institute of Technology,Harbin 150050,China)
出处 《中国给水排水》 CAS CSCD 北大核心 2019年第19期46-49,共4页 China Water & Wastewater
基金 国家自然科学基金资助项目(51778178) 国家重点研发计划项目(2016YFC0802402、2018YFC0406201-3) 深圳技术创新计划技术攻关项目(JSGG20170823140113498)
关键词 供水管网 漏损定位 流量数据 均值差分析 t检验分析 water supply network leakage location flow data mean difference test student' s t test
  • 相关文献

参考文献2

二级参考文献3

共引文献28

同被引文献88

引证文献8

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部