期刊文献+

一种适用于地下矿山分布式系统的高精度时间同步系统设计及实现 被引量:4

High precision time synchronization system designed and implemented for underground mine distributed system
下载PDF
导出
摘要 针对地下矿山分布式系统的时间同步问题,本文提出了一种适用于地下矿山分布式系统的高精度时间同步方法,基于IEEE1588-2008时间同步协议研发出了主时钟和从时钟,通过时间同步和频率同步的方式,并在不同网络环境下的进行时间同步测试,整个系统实现了亚微秒时间同步精度,有效解决了地下矿山分布式系统间的实时性问题。 For the problem of time synchronization of distributed system in underground mine,this paper presents a high precision time synchronization method suitable for underground mine distributed system.The master and slave clock are developed based on the IEEE1588-2008 protocol,and time synchronization and frequency synchronization are adopted.Finally,the whole system realizes the sub-microsecond time synchronization precision in different network environments,which effectively solves the real-time problem between distributed systems of underground mines.
作者 冀虎 张达 戴锐 石雅倩 JI Hu;ZHANG Da;DAI Rui;SHI Yaqian(BGRIMM Technology Group,Beijing 102628,China;Beijing Key Laboratory of Nonferrous Intelligent Mining Technology,Beijing 102628,China)
出处 《中国矿业》 北大核心 2019年第A02期219-222,共4页 China Mining Magazine
基金 国家重点研发计划课题资助(编号:2017YFC0602904)
关键词 地下矿山 分布式系统 时间同步 underground mine distributed system time synchronization
  • 相关文献

参考文献6

二级参考文献50

  • 1柯加山,刘毅.C^4ISR系统信息的军事价值评估[J].军事运筹与系统工程,2004,18(1):51-55. 被引量:13
  • 2马瑞.人工神经网络原理[M].北京:机械工业出版社,2010.
  • 3Qian W,Guo C,Mei J.Research of the precision clock synchronization based on IEEE 1588[J].Journal of Software(1796217X),2013,8(2):451-458.
  • 4Peng-Fei Y,Qiang Y,Hui D,et al.The research of precision time protocol IEEE1588[C]//The International Conference on Electrical Engineering,2009.
  • 5Sundararaman B, Buy U, Kshemkalyani A D. Clock syn- chronization for wireless sensor networks:a survey[J]. Ad Hoc Networks, 2006,3 (3): 281-323.
  • 6Philips J, Kundert K. Noise in mixers, oscillators, sam- piers,and logic: An introduction to cyclo stationary noise [C]//in Proc IEEE CICC. Orlando, FL: IEEE, 2000: 431- 438.
  • 7Shang F J. An energy-efficient communication protocol for wireless sensor networks[J]. Journal of Networks, 2011,6 (7) :999-1008.
  • 8Deeths D. Using NTP to control and synchronize system clocks, system clocks[M]. New York: Sun Micro-systems, Inc,2001.
  • 9Maroti M,Kusy B,Simon G,et al. The flooding time syn chronization protocol[C]//Proc 2nd ACM conf embedded networked sensor systems. New York: ACM, 2004 : 39-49.
  • 10Ganeriwal S,Kumar R,Srivastava M B. Timing-sync proto- col for sensor networks[C]//The first ACM conference on embedded networked sensor system. New York: ACM, 2003: 138-149.

共引文献10

同被引文献92

引证文献4

二级引证文献20