摘要 根据相关核安全法规,核电站的冷却水泵用电机为核安全2级,必须确保承受若干次安全停堆地震(OBE)和运行基准地震荷载(SSE)荷载之后,仍能保持结构完好性和安全运行功能。本文通过模拟地震振动台设备对1台1E级冷却水泵用电机进行白噪声和若干次人工波激振,获取了电机的基本动力特性,并通过在试验过程中对电机功能的监测和试验数据的分析,结论表明该电机在各地震工况下结构完好,各功能指标在抗震试验前后无明显变化,满足抗震要求。利用高置信度低概率失效(HCLPF)来量化设备的抗震裕度(SMA),采用核电站抗震裕度评估方法EPRINP-6041-SL中易于实施的保守的确定论失效裕度(CDFM)分析方法,合理选取其反应谱削波因子、抑制因子等主要参数,计算其抗震裕度比例因子,得到该电机的抗震裕度。 According tothe nuclear safety regulations,the cooling electromotor of nuclear power plant is nuclear safety 2E,which must be safety to withstand the several OBE and SSE earthquake excitation.In this paper,a class 1E cooling electromotor was studied by using the white noise scanning method and several artificial excitation waves though a shaking table tests.In the test,the dynamic characteristics of the motor are obtained,and the running condition of the motor is monitored.The results show that the class 1E motor was still in good condition after earthquake shock.The seismic margin of the equipment is quantified by the high confidence low probability failure(HCLPF).The conservative conclusion failure margin(CDFM)analysis method in EPRI NP-6041-SL report is easy to implement,and by it the the response spectrum clipping factor,inhibiting factor and other main parameters were selection and calculating the seismic margin factor,to get the seismic margin of the motor.
作者 周年强 施卫星 ZHOU Nianqiang;SHI Weixing(College of Civil Engineering Nanjing Forestry University,Nanjing of Jiangsu Prov.210037,China;Department of Disaster Mitigation for Structures,Tongji University,Shanghai,200092,China)
出处 《核科学与工程》 CAS CSCD 北大核心 2019年第5期782-788,共7页 Nuclear Science and Engineering
关键词 核电站 冷却电机 振动台试验 抗震鉴定 抗震裕度评估 高置信度低失效值 Nuclear Power Plant Cooling electromotor Shaking table test Seismic qualification Seismic margin assessment High confidence low probability failure(HCLPF)
  • 相关文献

参考文献5

二级参考文献20

  • 1方庆贤.核电厂设备抗震鉴定的审评[J].核动力工程,1995,16(5):394-400. 被引量:11
  • 2IEEE Std 344 - 1987. IEEE Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations [ S ]. New York: The institute of Electrical and Electronic Engineers, Inc. , 1987.
  • 3IEEE Std 387 - 1995. Standard Criteria for Diesel - Generator Units Applied as Standby Power Supplies for Nuclear Power Generating Stations[ S]. New York: The Institute of Electrical and Electronic Engineers, Inc. , 1995.
  • 4ASME BPVC-Ⅲ-I-ND-2001. ASME Boiler and Pressure Vessel Code, Section Ⅲ, Division 1, Subsection ND Class 3 Components[ S]. New York: The American Society of Mechanical Engineers, 2001.
  • 5ASME BPVC - Ⅲ - 1 - NF - 2001. ASME Boiler and Pressure Vessel Code, Section Ⅲ, Division 1, Subsection NF Supports [ S]. New York: The American Society of Mechanical Engineers, 2001.
  • 6杨仁安 赵国玺.核电站1E级设备的抗震鉴定试验.核动力工程,1988,:23-28.
  • 7GB13625-92.核电厂安全系统电气设备抗震鉴定[S].[S].,..
  • 8HAFJ0053.核设备抗震鉴定试验指南[S].[S].,..
  • 9GB50267-97.核电厂抗震设计规范[S].[S].,..
  • 10中华人民共和国建设部.GB50267-97核电厂抗震设计规范[S].北京:中国标准出版社,1997.

共引文献22

同被引文献17

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部