摘要 对双缸滚动转子式压缩机采暖热泵在环境温度(Tod)为-30~0℃,出水温度(Two)为41~50℃范围内的制热进行测试。研究表明:外界环境温度对排气温度、蒸发温度影响很大,对冷凝温度影响很小;热水出水温度对冷凝温度影响很大,对排气温度、蒸发温度影响很小。随着外界环境温度的降低,采暖热泵的制热量急剧下降,当Two=41℃时,Tod从0℃下降到-30℃,制热量的降幅达62.16%;随着出水温度的升高,采暖热泵的制热量下降缓慢,当Tod=0℃时,Two从41℃上升到45℃,制热量降幅仅为5.61%;外界环境温度对COPh值的影响也显著,当Two=41℃时,Tod从0℃下降到-30℃,COPh值从2.94下降到1.38,降幅达53.06%。双缸滚动转子式压缩机采暖热泵应用于-30~0℃的低温工况下,具有良好的实用价值。 The heating performance of space heating heat pump (SHHP) with dual-cylinder rotary compressor was tested at low ambient temperature (Tod) in the range of -30-0℃, and water outlet temperature (Two) in the range of 41-50℃. The results show that ambient temperature has great influence on its discharge temperature and evaporating temperature, but little on condensing temperature;hot water outlet temperature has great influence on its condensing temperature, and little influence on its discharge temperature and evaporating temperature. With the decrease of ambient temperature, the heat capacity of SHHP decreases sharply, when Two = 41℃, Tod decreases from 0℃ to -30℃, and the heat capacity decreases by 62.16%. With the increase of outlet temperature, the heat capacity of SHHP decreases slowly, when Tod = 0℃, Two rises from 41℃ to 45℃, the heat capacity decreases by only 5.61%. The influence of ambient temperature on COPh value is also obvious, when Two = 41℃, Tod decreases from 0℃ to -30℃, COPh decreases from 2.94 to 1.38, a drop of 53.06%. The SHHP with dual-cylinder rotary compressor has good practical value to be applied in low temperature condition of -30-0℃.
作者 尹应德 朱冬生 刘世杰 叶周 王飞扬 YIN Yingde;ZHU Dongsheng;LIU Shijie;YE Zhou;WANG Feiyang(Guangzhou Institute of Energy Conversion,Chinese Academy of Sciences,Guangzhou 510640,Guangdong,China;CAS Key Laboratory of Renewable Energy,Guangzhou 510640,Guangdong,China;Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development,Guangzhou 510640,Guangdong,China)
出处 《化工学报》 EI CAS CSCD 北大核心 2019年第A02期220-227,共8页 CIESC Journal
基金 湖北省中国科学院科技合作专项项目(2018-916-000-009) 中国科学院可再生能源重点实验室基金项目 2017佛山市顺德区科技计划项目 2017容桂科技计划项目(容桂经发〔2017〕27号)
关键词 低环境温度 采暖热泵 传热 压缩机 相变 性能系数 low ambient temperature space heating heat pump heat transfer compressor phase change coefficient of performance
  • 相关文献

参考文献11

二级参考文献106

共引文献166

同被引文献17

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部