摘要
在大高差长输供热管线中,分布式系统和中继泵站系统的应用具备不同的优势和缺点。论文以某城市的集中供热项目为实际案例,对分布式系统与中继泵站系统在大高差长输供热管线的应用优势与劣势进行了详细的对比。
In the heat supply pipeline with large height difference and long distance, the application of distributed system and relay pump station system has different advantages and disadvantages. Taking a central heating project in a city as an actual case, this paper makes a detailed comparison between the advantages and disadvantages of the distributed system and the trunk pump station system in the application of the heating pipeline with large height difference and long distance.
作者
王莹
李文君
WANG Ying;LI Wen-jun(North China Municipal Engineering Design & Research Institute Co. Ltd.,Tianjin 300074,China;China Construction Sixth Engineering Division Corp.Ltd.Water Conservancy and Hydropower Construction Group Co. Ltd.,Tianjin 300222,China)
出处
《工程建设与设计》
2019年第20期46-47,共2页
Construction & Design for Engineering
关键词
分布式系统
中继泵站系统
大高差长输供热管线
应用
distributed system
relay pumping station system
large height difference long distance heating pipeline