期刊文献+

混凝—臭氧氧化处理垃圾中转站渗滤液的试验研究 被引量:1

Treatment of the Landfill Leachate from waste transfer station by Coagulation-Ozonation Process
下载PDF
导出
摘要 以垃圾中转站渗滤液为研究对象,分析了混凝-臭氧氧化工艺对渗滤液COD和色度的影响。结果表明:在pH=11.2,FeCl3加量为900mg/L,臭氧反应时间为20min,臭氧流量为35mg/L的优化条件下,垃圾中转站渗滤液的COD、色度分别可去除78.39%与95.34,BOD5/COD由反应之前的0.152提升到了0.415,可生化性明显改善。 The effect of coagulation-ozonation process on COD and chroma removal of leachate from waste transfer station was analyzed.The results showed that under the optimum conditions(900 mg/L of FeCl3,and pH 11.2,and 20 min ozone reaction time,and 35 mg/L of ozone flow rate),COD and chroma of leachate from waste transfer station could be removed by 78.39%and 95.34 respectively,and BOD5/COD increased from 0.152 to 0.415,indicating that the biodegradability was significantly enhanced.
作者 廖书林 浦燕新 许龙霞 周梦凯 Liao Shulin;Pu Yanxin;Xu Longxia;Zhou Mengkai(WELLE Environmental Group Co.,Ltd.,Changzhou 213001,China)
出处 《云南化工》 CAS 2019年第9期57-58,共2页 Yunnan Chemical Technology
基金 污泥与废弃物处置及资源化利用技术集成与综合示范,课题编号:2017ZX07202005
关键词 渗滤液 垃圾中转站 臭氧 混凝 Leachate Waste transfer station Ozone Coagulation