7Roessler K,Ungersboeck K,Aichholzer M,et al.Frameless stereotactic lesion contour-guided surgery using a computer-navigated microscope.Surg Neurol,1998,49:282~289.
9Koyama H,Uchida T,Funakubo H,et al.Development of a new microsurgical robot for stereotactic neurosurgery.Stereotact Funct Neurosurg,1990,55:462~467.
10Andre O, Isabelle M.Frameless stereotaxy for surgery of the epi-lepsies:preliminary experience.J Neurosurg,1994,81:629~633.
二级参考文献10
1Roberts DW,Strohbehn JW,Hatch JF,et al. A frameless stereoraxic integration of computerized tomographic imaging and the operating microscope. J Neurosurg,1986,65:545-548.
2Watanabe E, Watanabe T, Manaka S,et al. Three-dimentional digitizer ( neuro-navigator ) , A new equipment for CT-guided stereotaxic surgery. Surg Neurol, 1987,27:543-547.
3Ziarecuich SJ , Tebo SA, Long DM, et al. Framelcss stereotaxic integratioa of CT imaging data, Accuracy and initial appticaliorts. Radiology, 1993, 188:735-745.
4Golfinos JG, Fitzpatrick BC, Smith LR, et al. Clinical use of a frameless stereotactie arm: results of 325 cases.J Netlrosurg, 1995, 83:197-205.
5Patel N , Saademan DR , Colly M , et al. Interative imageguided surgery of the spine use of the ISG/ELekta Viewing Wand to aid intraopcratine Localization of a sacral osteoblastomea, BJ Neurosurg, 1997, 11: 60-64.
6Sipoa EP, Tebo SA , Zinreich SJ, et al, In vivo accuracy testing and clinical experience with the ISG Viewing Wand. Nemosurgcry, 1996,39:194-204.
7Tan KK, Graeszczuk R. Levin DN, et al. A frameless stereotactic approach to neurosurgical planning based on retroapective patient-image registration. J Neurosurg,1993,79:296-303.
8Ryan MJ,Eroksoa RK , Lerin DN ,et al, Frameless sterotaxy with real-time tracking of patient head movement and retrospactive patient-image registration. J Neurosurg.1996,85:287-292.
9Vrionis FD, Foley KT, Rohertson JH, et al. Use of cranial surface anatomic fidudals for interative imageguided navigation in the temporal bone: a cadavcric study, Neurosurgery, 1997, 40:755-764.
10Maciunas RJ,Galloway RL, Jr. Latlmez JW, The applicntion accuracy of stcrcotactie frames. Neurosurgery,1994,35:682-695.
5Daneyemez M, Gezen F, Canakci Z , et al. Radical surgery and reoperation in supratentorial malignant glial tumors[J]. Minim Invasive Neurosurg,1998,41(4):209-213.
6Daneyemez M,Gezen F,Canakci Z,et al. Radical surgery and reoperation in supratentorial malignant glial tumors [J]. Minim Invasive Neurosurg, 1998,41(4) : 209- 213.?A
7Roberts DW,Strohlaehm JW,Hatch JF,et al. A frameless stereotaxic integration of computerized to mographic imaging and the operating microscope.J Neurosurge,1986,65(4): 545-549.
8Hartmut Kgfinos JG,Fitzpatrick BC,Darius CW, et al. BrainLAB vector vision neuronavigation system: technology and clinical experiences in 131 cases.Neurosurgery,1999,44: 97-105.
9Abdol KM, Sanan S, Van HR, et al. Petronlival meningiomas: predintive parameters for transpetrosal armoroanhes. Neurosurgery,2000,47: 139-150.
10Hirohata M,Abe T, Morimitsu H, et al. Preoperative selective internal carotid artery dural branch embolisation for petroclival meningiomas. Neuroradiology,2003,45(9):656-660.