摘要 提取定子电流信号的Park矢量图作为电机故障特征,应用人工神经网络技术对故障特征进行分类与识别,从而避开复杂的谱分析技术,实验测试结果表明,该方法用于电机故障诊断可靠、有效,是一种实际可行的电机故障诊断方法。 Park transform is applied to the malfunction diagnosis of induction, motor, avoiding complicated technology of frequency analysis. The current Park′s vector diagram of current signal of stator serves as malfunction characteristic of motor. And the malfunction Characteristic is sorted and correctness identified by artificial of nerve net technology. The experiment results has showed that the correctness of motor malfunction by this method identifying is very high. So it is a feasible method of motor malfunction diagnosis.
出处 《武汉科技学院学报》 2002年第5期87-90,共4页 Journal of Wuhan Institute of Science and Technology
关键词 PARK变换 感应电机 故障诊断 Park矢量图 人工神经网络 故障特征提取 park transform induction motor malfunction diagnosis
  • 相关文献

参考文献4

  • 1M.E.H.Benhouzid etal .Induction Motor disagnostics Via stator current monitoring[J].Mainterance and Reliability. Vol. 1,knoxv ille,TN, 1997,36:01 ~ 10.
  • 2管霖,吴国沛,黄雯莹,任震,周宏.小波变换在电力设备故障诊断中的应用研究[J].中国电机工程学报,2000,20(10):46-49. 被引量:36
  • 3T.W.S.chow. Conditoin Monitoring of electric Machines usrig third-order spectrum analysis[J] .Meeting ,Vol. 1 Lake Buena Vista,FL,PP. 1996,679~686.
  • 4张立明.人工神经网络模型及其应用[M].上海:复旦大学出版社,1989.

二级参考文献10

  • 1苏洪波,尹项根,陈德树.微机自适应式发电机定子接地保护的研究[J].电网技术,1996,20(11):59-61. 被引量:11
  • 2崔锦泰 程正兴(译).小波分析导论[M].西安:西安交通大学出版社,1995..
  • 3赵兴国 柏青海.新原理的发电机100%定子接地保护[J].电站设备自动化,1988,1:44-49.
  • 4肖遥 王维俭 等.发电机三次谐波电压及定子接地保护的再分析[J].电站设备自动化,1983,4:1-5.
  • 5王维俭,发电机变压器继电保护应用,1998年
  • 6程正兴(译),小波分析导论,1995年
  • 7刘贵忠,小波分析及其应用,1992年
  • 8赵兴国,电站设备自动化,1988年,1卷,44页
  • 9肖遥,电站设备自动化,1983年,4卷,1页
  • 10石志强,任震,黄雯莹.基于 B_小波的异步电机故障信号去噪和检测[J].电力系统自动化,1997,21(6):38-41. 被引量:21

共引文献35

同被引文献59

引证文献6

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部