期刊文献+

负重位全下肢一次成像摄片装置的研制与应用 被引量:1

Development and Application of One-time Imaging Set for Whole Low Extremities in Burdening Posture
下载PDF
导出
摘要 目的 :研制全下肢一次成像摄片装置 ,以获得一次摄取全下肢 X线影像。方法 :测量 30例患者双踝关节至双髋关节长度。确定所需 X光片的规格为 35 .5 cm× 96 .5 cm,设计专用摄片架并特制相应暗盒、增感屏及滤线器。结果 :5 0例全下肢 X线照片显示双踝关节至双髋关节影像诊断清晰 ,密度一致。结论 :一次成像全下肢 Objective To develop the imaging and photographic set so as to achieve one time X ray image of the total low extremities. Methods The lenth of both ankles and both hipbones of 30 cases were measured. The length of X ray film needed was 3.5 cm multipy 96.5 cm. Special support, cassete, intensifying screen and filter were designed. Results The films of 50 cases were very clear to show the whoe limbs and the density of film was uniform. Conclusion Accurate and reliab leimages provoided by one time image would get better effect of measurement for total low extrimty before and after operation.
作者 张新华 蒋青
出处 《实用医技杂志》 2002年第12期917-918,共2页 Journal of Practical Medical Techniques
关键词 设备设计 放射摄影术 全下肢 equipment design radiograph total low extremity
  • 相关文献

参考文献2

二级参考文献2

  • 1Don,L D,Boirdo.RA: Technical consideration in total knee arthroplasty[].Clinical Orthopaedics.1986
  • 2DorrLD,etal.Technicalfactorsthatmechanicallooseningoftotalkneearthroplasty[]..

共引文献32

同被引文献9

  • 1Wei X, Messner K. Maturation-dependent durability of spontaneous cartilage repair in rabbit knee joint. J Biome Mat Res, 1999, 46: 539-548.
  • 2Hui A J, McCalden RW, Martell JM, el al. Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg(Am), 2003, 85: 505-511.
  • 3Moreland JR, Bassett LW, Hanker G J. Radingraphic analysis nf the axial alignment of the lower extremity. J Bone Joint Surg(Am), 1987, 69: 745-749.
  • 4Lotke PA, Ecker ML. Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg(Arn), 1977, 59: 77- 79.
  • 5Prakash U, Wigderowitz CA, McGurty DW, et al. Computerised measurement of tibiofemoral alignment. J Bone Joint Surg(Br), 2001, 83: 819-824.
  • 6Jiang CC, Insall iN. Effect of rotation on tile axial alignment of the femur: pitfalls in the use of femoral intramedullary guides in total knee arthroplasty. Clin Orthop Relat Res, 1989, (248): 50-56.
  • 7Wright JG, Treble N, Feinstein AR. Measurement of lower limb alignment using long radiographs. J Bone Joint Surg(Br), 1991, 73: 721-723.
  • 8Lonner JH, Laird MT, Stuchin SA. Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res, 1996, (331): 102-106.
  • 9蒋青,宋知非,骆东山,朱丽华.双下肢全长负重位X线片在全膝关节置换术中的应用价值[J].中华骨科杂志,2002,22(5):284-287. 被引量:31