摘要
文章通过对专门设计的五种雷管结构的实验和分析,提出覆铜钢壳电雷管在受到静电危害时,首先药头被引燃,致使雷管爆炸。该论点对提高电雷管的抗静电能力,提供了一个可行的技术途径。
In this paper,five kinds of detonators specially designed and their structure have been investigated and analyzed.The results show that when coppor clad steel case electric detonator is under the hazards of static electricity,the fuse hesd is ignited and then the detonator is blasted.This conclution provides a practical technic way for improving the anti-static electric capacity of electric detonator.
出处
《爆破器材》
CAS
北大核心
1992年第3期16-18,共3页
Explosive Materials
关键词
感度
起爆药
药头
覆铜钢壳
电雷管
sensitivity
initiating explosive
fuse head
coppor clad steel case electric detonator