根据对浦东国际机场的实际情况的调研测试 ,找出了水泵运行存在的问题。提出了叶轮切削和变频调节的改造方案 ,分析了叶轮切削和变频调节各自的特点和经济性。得出了同时采用叶轮切削和变频调节 ,可以更有效地降低初投资 。
According to the field study on pumping system of Pudong international airport,analyses the issues exited.Put forwards some measures including impeller cutting and frequency conversion to improve the system energy efficiency.With using these techniques,the operation cost will be reduced.