摘要
以电解质中物相组成为基础,阐述了X射线衍射仪测定酸性铝电解质时,如何修正电解质中的氟化镁、氟化锂对测量的影响,解决了生产实际过程中控制分析需要。
The phase of electrolyte in aluminum electrolysis was studiedUsing the Philip Xray diffractiometry,how to modify the effect of magnesium fluoride and lithium fluoride on determining bath ratio in aluminum electrolysis was expatiatedThe results meet the need of controlling analysis during the production in factory
出处
《冶金分析》
CAS
CSCD
北大核心
2002年第5期32-34,共3页
Metallurgical Analysis
关键词
铝电解质
重量比
测定公式
修正
X射线衍射仪
:eletrolyte in aluminum electrolysis
determination
Xray diffractiometry