摘要
根据立体定向伽玛射线全身治疗装置的结构和原理 ,计算了治疗室内散射线的能量分布 ,并据此对某一实际治疗室的墙壁、顶棚和防护门进行了屏蔽设计。
According to the structure and principle of gamma stereotactic body radiotherapy equipment, the energy distribution of scatter radiation in the treatment room is calculated, and the shielding design for the wall, roof and the door of a certain treatment room was performed. (