期刊文献+

ICP-OES快速测定卤水中K、Na、Ca、Mg、B、Li的含量 被引量:1

Rapid determination of K,Na,Ca,Mg,B and Li in brine by ICP-OES
下载PDF
导出
摘要 开发了一种适合于ICP-OES快速测定卤水中K、Na、Ca、Mg、B、Li的含量分析方法,考察了ICP-OES光谱仪[1]主要的工作参数和工作条件,以及对谱线的影响,确定了检测范围,方法无需分离、简便、快速、准确。K、Na、Ca、Mg、B、Li检测方法的检测下限分别0.0057、0.012,0.0017,0.0066、0.0015、0.0084mg/L。方法的精密度(RSD,n=6)均小于2%,回收率为96.03%~107.6%。该方法与国标氯化钾GB6549—2011法[2]对比分析结果均在允许差范围之内。 The main working parameters and conditions of ICP-OES and the influences on spectral lines were studied,and the detection ranges were identified.The method was simple,fast,accurate and without sample separation.The detection thresholds for K,Na,Ca,Mg,B and Li were 0.0057,0.012,0.0017,0.0066,0.0015 and 0.0084 mg/L.The precision of the method(RSD,N =6)was below 2 %,and the recoveries were in the range of 96.03%—107.6%.The difference between this method and the GB6549—2011 method was within the permissible range.
作者 屈小荣 冯勇 吴泽培 么涵蔚 张娟 张正利 Qu Xiaorong;Feng Yong;Wu Zepei;Yao Hanwei;Zhang Juan;Zhang ZhengLi(Qinghai Salt Lake Industry Co.,Ltd.,Golmud816000,China;National Engineering Research Center for Comprehensive Utilization of Salt Lake Resources,Golmud816000,China;Key Laboratory of Salt Lake Resources Comprehensive Utilization of Qinghai Province,Golmud816000,China)
出处 《分析仪器》 CAS 2019年第2期70-74,共5页 Analytical Instrumentation
关键词 电感耦合等离子体发射光谱 快速测定 卤水 Inductively coupled plasma emission spectroscopy Rapid determination Brine
  • 相关文献

参考文献2

二级参考文献7

共引文献26

同被引文献11

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部