胸胸部CT扫描与X线平片对肺结核及肺癌空洞积液量的测量差异 被引量:4

Comparison of CT scanning and X ray in measuring the volume of the effusion for the cavity caused by pulmonary tuberculosis or lung carcinoma
下载PDF
导出
摘要 目的对比胸部CT扫描与X线平片对肺结核及肺癌空洞积液量的测量差异。方法收集同时进行X线胸片及胸部增强CT扫描确诊空洞并积液的肺结核及肺癌患者患者各36及32例,均在CT引导下行积液穿刺,对比3种测量方法下的积液量差异。结果结核及癌性空洞患者均表现为胸部增强CT所测得的积液量明显较X线平片多(P<0.05),且穿刺实际所抽出积液量同样较X线平片多(P<0.05),但胸部CT所测积液量与穿刺所得无统计学差异。结论对于同一患者在同一时间点,胸部CT增强扫描所测得的空洞积液量更加接近实际体积,提示CT的测量精度更高。 Objective To compare the CT scanning and X ray in measuring the volume of the effusion for the cavity caused by pulmonary tuberculosis or lung carcinoma. Methods We collected simultaneous X- ray sternum and breast enhancement CT scan confirmed empty and effusion of the 36 and 32 patients with tuberculosis and lung cancer patients, both in CT guiding effusion puncture, compare the three methods of measuring the amount of effusion. Results The tuberculosis hole and cancer patients were measured by enhanced CT chest effusion quantity more obvious than X- ray plain film(P<0.05), and piercing actual amount drawn effusion more equally than X- ray plain film(P<0.05), but the chest CT and the quantity measured effusion puncture income no statistical difference. Conclusion For patients with the same point at the same time, the chest CT enhanced scan cavity effusion quantity closer to actual measured by volume, prompt CT measurement precision was higher.
出处 《分子影像学杂志》 2015年第2期112-113,116,共3页 Journal of Molecular Imaging
关键词 肺结核 肺部肿瘤 空洞 胸部CT增强扫描 X线平片 tuberculosis lung cancer empty Chest CT enhanced scan X-ray plain film
  • 相关文献

参考文献9

二级参考文献72

共引文献82

同被引文献25

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部