对核相的方法和技术进行分析。一次核相大大降低变电操作人员工作强度、电网、设备风险。二次核相方法安全,可靠性高,但操作人员工作强度大、操作效率低。避免变电站进行倒闸操作引起的、电网、设备风险。
In this paper,the methods and techniques of phases are analyzed.The primary phase greatly reduces the work intensity,power grid and equipment risk of substation operators.Secondary phase checking method is safe and reliable,but the operator has high work intensity and low operation efficiency.It avoids the risk of power grid and equipment caused by switching operation in substation.