摘要
为了更好地改进超高层暖通空调的效果,论文中结合具体工程实例,就超高层建筑冷热源及水系统展开分析,讨论了超高层建筑的主塔楼水系统分区和设备泵压方案设计通过对换热损失的经济性比较,提出了设计方案,并对涉及方案进行了探讨和分析。
In order to improve the effect of super high-rise heating,ventilation and air-conditioning better,the cold and heat sources and water systems of super high-rise buildings are analyzed in this paper with specific engineering examples.Discusses the design of water system zoning and equipment pump pressure scheme for super high-rise building main tower.By comparing the economy of heat transfer loss,puts forward the design scheme,and discusses and analyses the related schemes.
作者
吴立人
WU Li-ren(Arcplus Group PLC.East China Architectural Design&Research Institute)
出处
《智能建筑与智慧城市》
2019年第7期31-33,共3页
Intelligent Building & Smart City
关键词
超高层建筑
暖通工程
冷热源
水系统
super high-rise building
HVAC engineering
cold and heat sources
water system