分析某水电机组大轴中心补气阀补气时的异常声响原因,提出补气阀换型改造方案,从机组摆度、振动、水压脉动、发电机噪音、补气阀补气量等方面对补气阀改造效果进行了评价。试验结果表明,补气阀改造后,机组稳定性整体上得到改善,发电机异常声响情况消失,补气量得到提高。
By analyzing the cause of the abnormal sound of the hydro-power unit,the reformation scheme of the air supply valve is proposed,and the modification effect of the air supply valve is evaluated from the aspects of the swing,vibration,hydraulic pressure pulsation,generator noise and the air supply volume of the valve of the unit.The test results show that after the modification of the air supply valve,the stability of the unit is improved as a whole,the abnormal sound of the generator disappears,and the air supply volume of the valve is increased.
作者
刘佳望
黄波
谢捷敏
LIU Jiawang;HUANG Bo;XIE Jiemin(Wuling Power Company Limited Tuokou Hydropower Plant,Huaihua 418106,China;Hunan Xiangdian Test Institute Co.,Ltd.,Changsha 410004,China)
出处
《湖南电力》
2019年第4期64-67,共4页
Hunan Electric Power
关键词
水轮发电机组
大轴中心
补气阀
hydro-generator unit
large shaft center
air supply valve