摘要 AP1000核电厂的稳压器顶部安装有两台弹簧式安全阀,用于提供超压保护。由于安全阀的口径较大,其排放能力及排放特性无法通过工业试验台架来验证。本文建立了安全阀的CFX动网格,并在此基础上进行动网格二次开发,编写外部命令,根据开启时间轴,实时替换计算网格,以模拟安全阀开启过程中截面的不断变化,进而分析安全阀的动态特性,为安全阀的排放特性评估提供了一定的依据。 Two spring safety valves are installed on the AP1000 pressurizer,which can provide overpressure protection for the reactor coolant system.Since the inlet pipe size of the safety valve is so large,it is impossible for the industrial test facility to carry out any test to verify the flow capability of this valve.This paper establishes a CFX dynamic grid for the safety valve,and develops this grid by preparing an external program to substitute the computation grid in real time to simulate the changing sections during valve opening.The dynamic flow characteristics are obtained,which can to some extent provide a reference for the evaluation of the valve.
作者 蔡志云 CAI Zhi-yun(Nuclear Power Institute of China,Chengdu,Sichuan Prov.610041,China)
出处 《中国核电》 2019年第3期280-283,共4页 China Nuclear Power
关键词 AP1000 安全阀 CFD 动态特性 AP1000 safety valve CFD dynamic characteristics
  • 相关文献

参考文献2

二级参考文献13

  • 1朱瑞安,臧希年,曹小一.稳压器汽腔小破口失水事故的模拟[J].核动力工程,1993,14(2):144-148. 被引量:3
  • 2Box P O. User's manual for the CENTS Code[Z], Vol.1,2005.
  • 3User's Manual of RELAP5/MOD3.2 Code[Z], Vol.2, NUREG/CR-5535, 1995.7.
  • 4Wiseman D A. AP 1000 Plant Parameters[Z], 2003.11.
  • 5AP1000 Plant Description and Safety Analysis Report[R], WCAP-15612 (Non-Proprietary), US Westinghouse Co. Ltd., PA,USA, 2000.
  • 6ZHENG Limin. Pressurizer volume demonstration analysis[R], Proceeding of 13th International Conference on Nuclear Engineering(ICONE13), ICONE13-50569, May 16-20, 2005, Beijing, China.
  • 7Westinghouse Electric Co. LLC. AP1000 design control document, Revision19 E R~. Westinghouse Electric Co. LLC. 2011.
  • 8Kamyab S, Nematollahi M. Performance evaluating of the AP1000 passive safety systems for mitigation of small break loss of coolant accident using risk assessment tool-II software [ J ]. Nuclear Engineering and Design ,2012,253:32 40.
  • 9Guimaraes A C F,Lapa C M F,Filho F F L Set al. Fuzzy uncertainty modeling applied to AP1000 nuclear power plant LOCA[J].Annals of Nuclear Energy,2011,38(8) : 1775-1786.
  • 10Wright R F. Simulated AP1000 response to design basis small-break LOCA events in APEX-1000 test facility [J]. Nuclear Engineering and Design, 2007, 39 (4) : 287-298.